Consider the following guidelines to reduce electromagnetic emissions from the machine.
Connect the machine to the input supply according to this manual. If disturban ces occur if may be necessary to take
additional precautions such as filtering the input supply.
The output cables should be kept as short as possible and should be positioned together. If possible connect the
work piece to ground in order to reduce the e lectromagnetic emissions. The operator must check that connecting
the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special
applications.

Technical Specifications

Input Voltage
230 V  10%
Single Phase
Duty Cycle
(Based on a 10 min. period)
20%
Welding Current Range
Fuse or Circuit Breaker Size
16 A Superlag
Height
345 mm
Operating Temperature
For any maintenance or repair operations it is recomm ended to contact the nearest technical service center or Lincoln
Electric. Maintenance or repairs performed by unauthorized service centers or personnel will null and void the
manufacturers warranty.
Input Power at Rated Output
2.5 kW @ 20% Duty Cycle
RATED OUTPUT AT 40°C
45-80 Amps
RECOMMENDED INPUT CABLE AND FUSE SIZES

PHYSICAL DIMENSIONS

Width
220 mm
–20°C to +40°C
INPUT
Output Current
70 A
OUTPUT RANGE
Maximum Open Circuit Voltage
Type of Plug
16A/250V
(Included with Machine)
Length
455 mm
9
Frequency
50/60 Hertz (Hz)
Output Voltage
17.5 Vdc
29 Vdc
Input Power Cable
3 Conductor, 1.5 mm
Weight
20.9 Kg
Storage Temperature
-25°C to +55°C