4.3

Technical Data NT 10000

Model
Recommended solar generator output
Nominal input
DC
Standby consumption
Night consumption
Injection starts from
Nominal voltage
UMPP voltage range
No-load voltage
Turn-on voltage
Turn-off voltage
Maximum current
Nominal current
Number of inlets
Maximum efficiency level
European efficiency level (weighted)
HERIC ® topology
AC
Nominal output continuous operation Pn
Maximum output Pp
Nominal frequency
Grid voltage
Grid voltage tolerance range
Nominal current per phase
Max. current per phase
Distortion factor with Pn
Reactive power factor (cos phi)
Current waveform
Solar Inverter NT 10000
7000–12000 Wp
11000 W
20 W
< 0.3 W
7 W
400 V
350 <= UMPP <= 750 V
850 V
420 V
340 V
10 A per MPP multitracking inlet
9 A per MPP multitracking inlet
1 per MPP multitracking inlet;
3 altogether
96.4 percent (with ventilator operation)
95.9 percent (with ventilator operation)
yes
10000 W
10000 W
50 Hz
400 V
-20 to +15 percent
14.5 A
18.2 A
< 3 percent
approx. 1
sine