Herunterladen Inhalt Inhalt Diese Seite drucken

Basic Settings - Sunways NT 10000 Benutzerhandbuch

Solar inverter
Vorschau ausblenden Andere Handbücher für NT 10000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2.2

Basic Settings

Setting the Fixed Voltage Level
Your Sunways Solar Inverter is equipped
with a precise MPP control. If less than
200 watt are injected, the control of the
energy unit concerned operates at a fixed
voltage level. That prevents unnecessary
MPP searching. To minimise adjustment
losses during fixed voltage operation, the
fixed voltage level of each energy unit of
the Solar Inverter can be set separately.
The optimum fixed voltage level depends
on your PV generator model.
Fixed voltage
No-load voltage
level
PV generator at 25 °C
420 V
≤ 630 V
540 V
> 630 V
The fixed voltage can be set with the slide
switch «S100» on the control circuit board.
Ex works, the switch is set to «420V».
To set a fixed voltage of 540 V, slide the
switch to the «540V» position.
«420 V» position
Illustr.: Slide switch «S100» for setting the
fixed voltage level
103
«540 V» position
GB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Nt 8000

Inhaltsverzeichnis