7 7 7 7
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a moist, lint-
free cloth. Never use alcohol or solvents! There are no serviceable parts
inside the device. If defective, please dispose of the unusable LED strip in
accordance with the current legal regulations. Should you have further
questions, please contact your dealer.
...............................................................................................................................................
8 8 8 8
TECHNICAL SPECIFICATIONS
Control unit:
Power supply:
Power rating:
Power consumption set:
Control channels:
Dimensions:
Wireless remote control:
Carrier frequency:
Battery:
Coverage:
Dimensions:
LED strip:
Power supply:
Watts per meter/total:
Protection grade:
Number of LEDs
Cutting mark:
Dimensions, weight:
www.eurolite.de
DANGER TO LIFE!
12-24 V DC via supplied PSU connected to
100-240 V AC, 50/60 Hz ~
max. 6 A per channel
45 W
4 (R, G, B, W)
85 x 45 x 23 mm
2.4 GHz ISM band
2 x AAA (not included)
30 m (in buildings), 50 m (in the open air)
110 x 52 x 20 mm
12 V DC, 3.5 A
8 W/max. 40 W
IP 68
300, type SMD
every 100 mm
Ø 12 x 5000 mm, approx. 400 g
23