Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Overheating Protection - UNITED OFFICE 281849 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical data

Mains voltage
Nominal current
Rated power
Protection class
Large waste container capacity
Cutting process for paper
Working width
Cutting capacity

Overheating protection

This appliance is fitted with overheating protection. If the motor overheats due to
overloading, the appliance switches itself off automatically.
If this occurs, proceed as follows:
WARNING – RISK OF INJURY!
Remove the power plug from the wall socket to avoid unintended starting
of the appliance.
Switch the appliance off by moving the switch
Empty the waste containers
Allow the appliance to cool down.
Put the mains plug back into the socket.
Switch the appliance on, by moving the switch
We recommend that you let the appliance cool down for about 30 minutes after
3 minutes of operation.
UAV 250 A1
220 - 240 V ~ , 50 Hz
approx. 1.2 A
250 W
II /
21 litres
Cross-cut,
5 x 18 mm particles
Safety level 4
220 mm
10 sheets (80 g/m
to the middle position "OFF".
/ .
into the "AUTO" position.
2
)
GB │ MT
 15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Uav 250 a1

Inhaltsverzeichnis