Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
INSTALLATION SERVICE
Before installation
1. Please read this manual carefully before
installation.
2. The appliance must be installed according to
national wiring rules and according to this
manual by qualified technicians.
3. Any change of installation position must be
handled by professionals;

SAFETY PRECAUTION

1. The power supply must be of rated voltage
with special circuitry for the appliance. The
normal operating range of voltage is
90%~110% of rated voltage. The diameter of
the power cord must comply with
requirements.
2. The user power supply shall have a reliable
grounding terminal. It is prohibited to connect
the grounding wire to the following items: 1)
Water Supply Pipe 2) Gas Pipe 3) Sewage Pipe
4) Other positions that are considered unsafe
3. Ensure safe grounding and a grounding wire
connected with the special grounding system of
the building, installed by professionals. The
appliance must be fitted with electrical leakage
protection switch and an air switch with
sufficient capacity (Refer to the following
chart). The air switch must also have a
magnetic and a thermal tripping function to
ensure protection in case of short-circuit and
overload.
Required Capacity of air break
Model
switch
9k
16A
12k
16A
4. Make sure that the power supply cord is long
enough to allow the right connection. Do not
use any extension cord for power supply.
4. Check the product to verify that it has not been
damaged before installation.
5. Mount with the lowest moving parts of indoor
unit at least 2.5 m above floor or grade Level.
6. After installing, the consumer must operate the
appliance correctly according to this manual,
keep a suitable storage for maintenance and
move of it in the future.
5. If the supply cord is damaged, it must be
replaced by the manufacturer or its service
agent or a similarly qualified person in order to
avoid a hazard.
6. An all-pole disconnection switch having a
contact separation of at least 3mm in all poles
should be connected in fixed wiring.
7. Risk of electric shock can cause injury or death:
Disconnect all electric power supplies before
servicing.
8. The connection of power cord and the cable
connection between indoor unit and outdoor
unit shall be in accordance with the wiring
diagram attached on the appliance.
9. Once installation is completed, the electric
components must not be accessible to the
users.
10. Use two or more people to move and install
the appliance to avoid excessive weight hazard.
11. After unpacking the air conditioner, keep all
packaging materials well out of the reach of
children.
12. According to the character of refrigerant
(R410a), the pressure of the tube is very high,
so be sure to careful when you install and
repair the appliance.
46

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Amd 055

Inhaltsverzeichnis