6. Power supply.
This charger should be used with original power
adapters only. When the charger is powered up, LCD
display turns ON, if there are no batteries inserted the
"null" icon should appear.
7. Basic operation.
Once rechargeable batteries are inserted, their voltage
level will be shown on the LCD display (for example 1.12V).
Voltage readings will be shown for the first 3 seconds, and
afterwards for the next 3 seconds display will show
"400mA" as default charging current. If not interrupted by
"Mode" and/or "Current" buttons within 6 seconds, the
default charge mode will start automatically. Operation
mode can be changed for all inserted batteries
simultaneously, anytime by holding "Mode" button, and if
change of electric current value is desired this operation
should be followed by pressing "Current" button. These
changes can be also made individually for each charging
slot by selecting "Slot" before holding "Mode" button.
The charger has the unique capability to detect and charge
near zero voltage cells. It will allow to charge every cell
with the open circuit voltage of min. 0.01V.
Mode selection.
Pressing and holding "Mode" button for about 2 seconds
activates mode change for all charging slots. Then short
7