Stage 1. Charging.
Various information can be read by pressing "Display" button – time of
operation, charging current, voltage level, charged capacity in mAh/Ah.
Stage 2. End of charging process, trickle charge is applied
to maintain full charge of the inserted batteries.
Icon "Full" will be shown on display. Pressing "Display" button will show
various information – time, trickle charging current, voltage level, charged
capacity in mAh/Ah - please note it is not the same value as battery's
rated capacity.
Discharge mode – can be used to reduce and minimize
memory effect and lazy battery effect. Such cell will be
discharged to level of 0.9V. Please note that the cell stays
discharged after completing this process. Further action
will be needed to charge the cell.
Can be also used to discharge (test) primary (i.e. alkaline)
batteries. Please note that you should not try to recharge
primary, non-rechargeable batteries.
Stage 1. Discharging.
Pressing the "Display" button will show various information – time,
discharging current, voltage level, momentary capacity in mAh/Ah. When
complete, "0mA" current will be shown and the capacity measured during
the operation can be displayed. This advanced function can be used i.e. to
test the self discharge rate of the cells.
Refresh mode – a special combination of several charge
and discharge cycles. The charger tries to maximize the