CLIMATE SYSTEMS AND ZONES
Multiple climate systems are used when different supply
temperatures are required for different parts of the system,
for example when both underfloor heating and radiators are
fitted in a property.
Climate systems can be divided into multiple zones. A zone
can be a specific room, and it is also possible to divide a large
room into several zones, with the help of radiator thermo-
stats.
Each zone can contain one or more accessories, e.g. room
sensors or thermostats, both wired and wireless.
2
2
1
1
This example shows a property with two climate systems (1
and 2, two separate floor levels) divided into four zones (1-4,
four different rooms). With a controlled radiator valve (SRV
10), the temperature can be controlled individually for a
zone.
REPEATER RPP 10
If the communication is weak between the main product
and an accessory in a zone, a repeater (RPP 10) may need
to be installed to amplify the signal between the zones.
1
2
3
Main product
RMU S40 | EN
3
4
12
9
3
6
1
2
3
Repeater
WIRELESS CONNECTION
1.
Follow the instructions in the guide in the main product's
menu 5.4 – "Wireless units".
2.
Select "Wireless" in menu 2 - "Installation" in RMU S40.
3. Make settings for RMU S40 in the main product's menu
1.3.3 – "Room sensor settings".
NOTE!
Also see the Installer Manual for the main product.
WIRED CONNECTION
1.
In menu 7.2.1 – "Add/remove accessories" in the main
product, you tell the main product which accessories
are installed. To identify connected accessories auto-
matically, select "Search for accessories". It is also pos-
sible to select accessories manually from the list.
2.
Select "Wired" in menu 2 - "Installation" in RMU S40.
3. Assign RMU S40 an address (a unique number) in menu
2 - "Installation".
If there is a communication fault between RMU S40 and
the main product, you will be asked to check the selec-
ted address and adjust if necessary.
4. Make settings for RMU S40 in the main product's menu
1.3.3 – "Room sensor settings".
NOTE!
Also see the Installer Manual for the main product.
CREATE PROFILES
MAIN PRODUCT MENU 4.3 - "PROFILES"
Here, you create profiles and select the zones and functions
to which the profiles will have access. A profile might, for
example, be an apartment with its own accessories.
Examples of functions:
•
heating
•
hot water
•
alarm
•
home/away
•
cooling
You can find more information about climate systems and
zones in the main product's Installer Manual.
1.
Create and name a profile (up to eight profiles).
2.
Select one or more zones. In order for RMU S40 to be
connected to the profile, it must be located in one of
the zones you select.
3. Add the functions to which the profile is to have access.
4. The room unit's display shows which profile it belongs
to.