Power & Relay Connector
6-pin terminal block with built-in relay for:
• External devices
• Auxiliary power (DC output)
• 0 V DC (-)
Connect locks and loads to the pins according to the hardware pin chart
generated through the hardware configuration.
Function
Pin
1, 4
0 V DC (-)
2–3
Relay
5
12 V DC
6
24 V DC
Important
The output circuits in this section are Class 2 power limited.
Tampering Alarm Pin Header
Two 2-pin headers for bypassing:
• Back tampering alarm (TB)
• Front tampering alarm (TF)
Function
Back tampering alarm
Front tampering
alarm
Note
Both the front and back tampering alarms are connected by default. The casing open
trigger can be configured to perform an action if the door controller is opened or if the
AXIS A1001 Network Door Controller
Notes
For connecting relay devices. Use the
hardware pin chart. See Configure the
Hardware on page 41.
The two relay pins are galvanically
separated from the rest of the circuitry.
For powering auxiliary equipment.
Note: This pin can only be used as
power out.
Not used
Pin
Notes
1–2
To bypass the front and back tampering alarm
simultaneously, connect jumpers between TB 1, TB 2 and
1–2
TF 1, TF 2 respectively. Bypassing the tampering alarms
means that the system will not identify any tampering
attempts.
27
Specifications
0 V DC
Max current = 700 mA
Max voltage = +30 V DC
Max voltage = +12 V DC
Max load = 500 mA
EN