Becker Centronic SunWindControl SWC52 Montage & Betriebsanleitung Seite 33

Sonnen-wind-steuergerät ihne sensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection as a group controller
Attention
If the control is used as a group control device, for example, no bridge
can be inserted between the L and C terminals!
1. Connect the power supply unit to the SWC52 as follows:
green/yellow
blue
brown/black
black/brown
bridge
UC52
single
central
command
command
2. Put the protective caps back on the power supply unit.
3. Fix the power supply unit in the box.
4. Put the operating device in the frame and plug it into the power supply unit.
Tubular drive
bridge
SWC52
central
Sensor
command
Tubular drive
green/yellow
blue
brown/black
black/brown
UC52
single
central
command
command