Functions and features

The through-beam sensor detects objects and materials without
contact and indicates their presence by a switched signal.
Range (r): see type label.

Electrical connection

The device shall be supplied from an isolating source and pro-
tected by an overcurrent device such that the limited voltage cir-
cuit requirements in accordance with UL 508 are met.
Isolate power, then connect the unit (see page 17 or type label).
Core colours (for sensors with cable connection): BN = brown,
BU = blue, BK = black.
Programming of the output function by wiring (see page 17 or type
label). Load of the function check output (fc output): max. 10mA.

Installation

receiver
push button
LEDs red, yellow, green
Fix the receiver (type OGE-...) in position.
Align the transmitter (type OGS-...) towards the receiver and tighten in
the same way. Maximum range is only possible with precise alignment.
NB: Commissioning
The through-beam sensor is supplied ready to operate (plug and play)
set at the max. sensing range. This is sufficient if the through-beam
sensor can operate with maximum excess gain (highest contrast). The
following setting procedures should only be necessary in less straight-
forward applications, for example if partly transparent objects must be
detected.
transmitter
LED green
7