Functions and features

In conjunction with a prismatic reflector or reflective tape the retro-
reflective sensor detects objects and materials without contact and
indicates their presence by a switched signal.
Standard range: OTR...: 0,15 - 5m;
OTP... (retro-reflective sensor with polarizationfilter): 0,2 - 2 m;
(values referred to prismatic reflector with Ø 80 mm).

Installation

Place prismatic reflector / reflective tape in desired position. Align the
photocell to a mounting device.
Maximum range is only achieved with precise alignment.

Electrical connection

Disconnect power before connecting the sensor.
Connection strictly to the indications on the type label.
Core colours: BN = brown, BU = blue, BK = black.