Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Declaration Of Conformity - STEINEL IR 180 UP Bedienungsanleitung

Sensorschalter
Vorschau ausblenden Andere Handbücher für IR 180 UP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Troubleshooting

Malfunction
Cause
Sensor Switch
a
Fuse blown,
without power
not switched ON
a
Short circuit
a
Sensor switch NF 50 UP
in two-way switch oper-
ation with other switches
a
Sensor Switch
Light bulb burnt out
does not switch ON
Troubleshooting
Malfunction
Cause
Sensor Switch
a
Twilight setting in
does not switch ON
night-time mode during
daytime operation
a
Additional two-way
switch OFF
a
Fuse blown
Sensor Switch
a
Continued movement
does not switch OFF
within the detection zone
a
Switched ON light is
within detection zone of
IR 180 UP and switches
ON again as a result of
temperature change
a
Permanent light operation
switched ON
(red LED illuminates)
a
Other Sensor Switch
is parallel-connected
and still active
Sensor Switch
a
Switched ON light is
keeps switching ON/OFF
within IR 180 UP detec-
tion zone
a
Animals moving in
IR 180 UP detection zone
a
Curtains, fl owers, etc.
move within the detection
zone of the HF 360 UP
and cause switching
again by motion
(IR 180 UP / HF 360 UP / NF 50 UP)
Remedy
a
Replace fuse; switch
ON mains switch; check
wiring with voltage tester
a
Check connections
a
NF 50 UP not capable of
two-way switch operation
a
Replace light bulb
(only for IR 180 UP / HF 360 UP)
Remedy
a
Readjust
a
Switch power on
a
New fuse,
check connection if
required
a
Check detection zone
a
Check detection zone
a
Switch off permanent
light operation
a
Await time setting of the
other Sensor Switch
a
Check detection zone
a
Check detection zone
a
Check detection zone
- 20 -
Operation/Maintenance
The Sensor Switch is suit-
the sabotage protection pre-
able for automatic or con-
scribed for this purpose. The
tact-free switching (NF 50
surface should be cleaned
UP) of light. The unit is not
if dirty with a damp cloth
suitable for special burglary
(without cleaners).
alarm systems, since it lacks

Declaration of conformity

The product complies with the following directives:
Low voltage directive
2006/95/EC with amendment
EMC directive
2004/108/EC with amendment
HF 360 AP:
R & TTE guideline
1999/5/EC with amendments concerning radio units and
telecommunication facilities
Functional Warranty
This STEINEL product has
The warranty period is
been manufactured with
36 months, starting on the
great care, and its oper-
date of sale to the user.
ation and safety have been
We undertake to remedy
tested in conformity with the
faults caused by material
current regulations. Produc-
or manufacturing defects.
tion is also submitted to
This warranty undertaking
fi nal random-sample testing.
shall be performed by the
STEINEL undertakes the
repair or replacement of the
guarantee for perfect condi-
defective parts, at our own
tion and function.
discretion.
This warranty shall not
cover damage to wearing
parts or damage and faults
caused by incorrect oper-
ation or maintenance.
Further consequential
damage to external items
is excluded.
Claims under warranty
shall only be accepted if
the product is sent fully
assembled and well packed
complete with sales slip or
invoice (date of purchase
and dealer's stamp) to the
appropriate Service Centre
or handed in to the dealer
within the fi rst 6 months.
Repair Service:
Our Customer Service
Department will repair faults
not covered by warranty or
after the warranty period.
Please send the product
well packed to your nearest
Service Centre.
- 21 -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hf 360 upNf 50 up

Inhaltsverzeichnis