Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Elements And Connections; Safety Notes; Applications - Monacor DCM-300 Bedienungsanleitung

Digital-stromzangen-multimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Please unfold page 3. Then you can
always see the operating elements
and connections described.
Contents
1
Connections . . . . . . . . . . . . . . . . . 9
2
Safety Notes . . . . . . . . . . . . . . . . 9
3
Applications . . . . . . . . . . . . . . . . . 9
4
4.3 Voltage measurement . . . . . . . . 11
continuity test . . . . . . . . . . . . . . . 11
value . . . . . . . . . . . . . . . . . . . . . 12
5
Battery Replacement . . . . . . . . . 12
6
Specifications . . . . . . . . . . . . . . 13
1 Operating
Connections
1 Current clamp
2 Push-button to open the current
clamp
3 Button "PEAK" to "freeze" the max.
measuring value in case of AC cur-
rent measurements
4 Display
5 Connection for the red test lead
(positive pole) for voltage measure-
ment
6 Jack "COM" for the black test lead
(negative pole)
7 Button "H" for "freezing" a measuring
value
8 Range switch
9 Button "MAX" for freezing the max.
measuring
value
"PEAK" (3) in case of AC current
measurements;
urement without max. value function]
10 Jack "+" for the red test lead (positive
pole) for measurements of resist-
ance, diode, and frequency
Elements
and
[press
button
frequency
meas-

2 Safety Notes

This meter corresponds to the directive
for electromagnetic compatibility 89/336/
EEC and to the low voltage directive
73/23/EEC.
With this meter very high voltages
dangerous to life can be measured.
Be especially careful with voltage
measurements from 42 V on. The test
leads must always be perfectly insu-
lated. Damaged test leads must be
replaced.
It is necessary to observe the following
items:
The meter is suitable for indoor use
only. Protect it against humidity and
heat (admissible ambient temperature
range 0 - 40 °C).
For cleaning only use a dry, soft cloth.
Do not use any chemicals or water.
If the valid safety precautions for
handling voltages from 42 V on are not
observed or if the meter is used for
purposes other than originally intend-
ed, if it is operated or connected in the
wrong way, overloaded or not repaired
by authorized personnel, no liability
can be taken over for possible dam-
age.
If the meter is to be put out of opera-
tion definitively, it must be disposed of
in a local recycling plant.

3 Applications

This digital clamp-on multimeter mainly
serves for measuring AC currents (0.1 to
700 A) in current circuits with low voltage
up to max. 600 V. The measurement is
made via a current clamp in an inductive
and thus contactless way so that the cor-
responding line must not be opened up.
DC and AC voltages, resistances,
diodes, and frequencies can additionally
be measured via connection jacks. For
continuity measurement a buzzer is pro-
vided.
GB
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis