DEVICE DEFAULT SETTINGS

The settings described below are defaults that you will need for initial commissioning.
5.1

AED9401A or AED9501A

Settings in the AED9401A basic device (see Fig. 6.1 on page 11):
u
Select bus CANopen or DeviceNet: Switch S2
u
Bus terminator to on: Switch S1
u
Bus isolator to off: Switch S3
Settings in the AED9501A basic device (see Fig. 6.2 on page 13):
u
Select bus CANopen or DeviceNet: Switch S2
u
Bus terminator to on: Switch S1
5.2

AD103C in AED

Settings in the AD103C (factory settings):
S
CAN bus address: 63; DeviceNet address: 63
S
CAN baud rate: 125000
S
Diagnostics bus address: 31
S
Diagnostics bus baud rate: 38400
5.3

FIT

Settings in the FIT (factory settings):
S
CAN bus address: 63; DeviceNet address: 63
S
CAN baud rate: 125000
S
Diagnostics bus address: 31
S
Diagnostics bus baud rate: 38400
8
®
FIT
-AED-Kit
DEVICE DEFAULT SETTINGS