Inverter Number ... WR-Nummer
If the data logger is to control various inverters, each inverter must be
assigned a particular number. If only one inverter is to be controlled, set
this value to 001.
KEY CONFIGURATION AND FUNCTIONS IN SETUP
MENU
Use the Setup Menu to change the parameters described above.
Note! Below key functions only apply after changing to the Setup Menu
according to the procedure described below. For an easier understan-
ding, please study below example.
Key "Illumination" .......... Skip parameter
Key "Scroll" .................... Select parameter for modification
Key "Illumination" .......... Increasing parameter value by 10
Key "Stand-By" .............. Increasing parameter value by 1
Key "Scroll" .................... Store modified parameter
Explanatory Example
The factory-setting for the time interval of start-up and control phase is
to be changed from 10 seconds to 120 seconds.
- In Power Supply Mode, press "Stand-By" key to change into start-up
and control phase.
- During start-up and control phase, again press "Stand-By" key to
change into Stand-By Mode.
- Now Sunrise is in Stand-By mode. Press "Stand-By" key to change to
Setup Menu.
- Press "Illumination" key twice to skip parameters "U_DC_FIX" and
"Fixspannung" and select "Start-up time". The preset start-up time is
displayed. One unit corresponds to 5 seconds (e.g. 002 = 2 x 5 sec.
= 10 sec. start-up time)
- Press "Scroll" key to activate parameter for modification.
- Press "Illumination" key twice to increase parameter value by 20.
- Press "Stand-By" key two times to increase parameter 2 times by 1.
- Press "Scroll" key to store new parameter value and select next
parameter.
- Press "Illumination" key to skip "PC-Data" parameter (not to be
modified).
- Press "Illumination" key to skip "WR-Nummer" parameter (not to be
modified).
The inverter is back in the start-up and control phase which then lasts 120
seconds. For any parameter modifications, proceed according to this
example.
Note! If you want change your parameter settings to the values as preset
by Fronius, see below table.
Parameter
U_DC_FIX
Fixspannung (fixed voltage)
Startzeit (Start-up time)
PC-Data (Data transfer)
WR-Nummer (Inverter #)
Tab.3
Fronius Factory Settings of Sunrise
37
Factory Setting
200
000
002
000
001