Spare Parts

Only use original Kärcher spare parts. You
will find a list of spare parts at the end of this
document.
Troubleshooting
You can rectify minor faults yourself with the
help of the following overview.
If in doubt, please consult the authorized
customer service.
Risk of injury
Always switch off the appliance and pull out
the mains plug before care and maintenance
work.
Warning
Repair works may only be performed by the
authorized customer service.
Machine does not start
" Check whether the voltage indicated on
the type plate corresponds to the voltage
of the socket.
" Check the power cord for damage.
Pressure does not build up in the
appliance
" Check the setting at the spray lance.
" Appliance ventilation: Switch on the
appliance without connection the HP
hose and run it until the water
discharging from the HP outlet is free of
bubbles. Switch off appliance and
reconnect spray lance.
" Clean the filter in the water supply
connection: This can be easily removed
using flat-nose pliers.
" Check all supply lines to the HP pump for
leaks or blockages.
Strong pressure fluctuations
" Clean the high-pressure nozzle:
Remove dirt and debris from the nozzle
bore with a needle and rinse through with
water towards the front.
" Check the volume of incoming water.
HP pump leaking
" Slight leakage from the HP pump is
normal. If the leakage increases contact
the authorized customer service.
No detergent infeed
" Select the low-pressure setting for the
spray lance.
" Clean the filter of the detergent suction
hose.
" Check the DT suction hose for kinks.
Specifications
Power connection
Voltage (1~50 Hz)
Connection output
Mains fuse (slow-blow)
Protective class
Water connection
Max. feed temperature
Min. feed volume
Feed pressure,
Performance data
Working pressure
Max. permissible pressure
Water flow rate
Detergent flow rate
Recoil force of handgun
Hand-arm vibration (ISO
5349)
Sound pressure level Lpa
(EN60704-1)
Sound power level Lwa
(2000/14/EG)
Dimensions
Depth
Width
Height
Weight
220 - 240 V
2,1 kW
10 A
I
40 °C
10 l/min
0,2 - 1,2 MPa
12,5 MPa
13 MPa
7,5 l/min
0,3 l/min
20 N
2,2 m/s
2
79 dB(A)
95 dB(A)
420 mm
445 mm
590 - 930 mm
21 kg