Technical Data/Safety Instructions - PHARO 29 450 000 Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

T e c h n i c a l D a t a
S a f e t y I n s t r u c t i o n s
Technical Data
Minimum flow pressure:
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temperature:
Temperature scale:
Safety stop:
Flow capacity at 3 bar
Hand shower:
Body showers:
Overhead shower:
Overhead shower + body showers:
Operative as from 2 bar.
Two consumers at the most may be active at the same time.
Minimum bathroom height 2.40 m.
38
Safety instructions for
Cocoon connection with lighting:
1.5 bar
max. 10 bar
Only a socket is required to connect the Cocoon to the power
2-5 bar
supply. An external transformer serves as power supply for the
10 bar
lighting.
max. 60 °C
60 °C
Electrical socket installation must only be performed by a
20 – 60 °C
qualified electrician. The complete power supply runs via a
38 °C
230 V/50 Hz AC connection.
The relevant national regulations in the applicable version must
12 l/min
be observed during electrical installation. Installation and
16 l/min
inspection tasks must be performed by authorised electricians.
18 l/min
All work on the Cocoon must be performed with the power
22 l/min
disconnected.
The transformer performance of the external transformer is
30 VA. A wiring conduit with a diameter of at least 25 mm
must be provided to install the power supply cable (see
page 44). The cable provided allows the transformer to be
installed in the dry area (protection zone 3), max. approx. 7 m
from the Cocoon. The transformer must be accessible at all
times. A damaged connection cable cannot be replaced, and
the transformer must not be operated in this case.
Flow heater:
The Cocoon can be used in combination with hydraulically,
electronically and thermally controlled flow heaters (min. 24
kW) when the minimum flow pressure is at least 1.5 bar. Due
to the lower warm water capacity of the flow heater, only one
consumer can be used at any one time. The warm water
temperature at the supply connection must be at least 2 °C
above the desired mixed water temperature.
Pressure differences
The pressures of the cold and hot water connections must be
balanced.