Herunterladen Inhalt Inhalt Diese Seite drucken

Included In Delivery; Description Of Individual Components; Operation - Conrad 12 05 99 Bedienungsanleitung

Multitester
Vorschau ausblenden Andere Handbücher für 12 05 99:
Inhaltsverzeichnis

Werbung

Guide the measuring tip of the MS18-2 along
an electric cable, electrical outlet or the device.
If there is voltage, (plug in socket, device
switched on, etc.) the LED (2) starts blinking. In
this way e.g., interruptions in cables etc. can be
detected simply and quickly.
Note: to increase the sensitivity, the battery
compartment lid can be touched with the fin-
ger.
This test can not be carried out with shielded
cables.
To carry out a quick test on electrical outlets,
power supply units or PVC insulated cables
hold the MS18-2 on the measuring tip (1) and
guide the grip near the device to be tested.
If there is voltage, the LED (2) will start blinking.
Direct voltage test (1.2 to 35VDC)
- With this function the MS18-2 identifies the polarity of direct volt-
age sources such as batteries, rechargeable batteries, etc.
Touch the pole of the battery to be tested with one finger. Touch
the other pole of the battery with the measuring tip (1) (touch bat-
tery compartment lid).
If the LED (2) starts to blink, the pole with which the measuring tip
is connected, is the positive pole. If the LED stays dark, touch the
minus pole.
"+" Pole, LED blinks
18
"-" Pole, LED dark
Included in Delivery
Multitester MS 18-2 · two round cell batteries· operating instructions

Description of individual Components

1. Measuring tip
2. LED display

Operation

Inserting the Battery/ Changing of Battery
To operate the multitester two round cell batteries type 392A, AG3,
LR41, 192 (or identically constructed) are needed.
To avoid an electric shock the multitester must not be
operated when open. After each battery change a self-
test needs to be carried out.
To change the batteries you need to:
- Open the battery compartment at the end of the grip with a suit-
able screwdriver (3). Opening = turn left (anti-clockwise). Also see
illustration below.
- Take out the battery compartment lid (3). Carefully bend back the
wire clip which holds the round cell batteries.
- Now take out the empty round cell batteries and replace them
with two new others of the same type. Take care to observe the
polarity of the round cell batteries.
3. Battery compartment lid