Maintenance

7.1

Maintenance work

Proper operation of the Wöhler RP 72 Soot Test
Pump requires regular maintenance. .
Interval
After each working day
Regularly
Twice a year
Maintenance
Maintenance work
Airing and drying of
the soot test pump:
Take out plug (7) and
(25).
Exchange wet cot-
tonwool filter rolls
(13)
Open the measuring
head (1).
Clean the measuring
probe with the probe
cleaning brush (see
accessories).
Greasing the sleeve
(22)
Loosen the screws
(9) and take off the
piston guide (19).
Pull out piston (21)
and sleeve (19).
Clean sleeve (22)
and pump pipe (9)
with a soft cloth from
the inside, put piston
21 with sleeve (22)
back into the pipe
and squirt a little
special maintenance
lubricant on the back
of the sleeve.
Check the accuracy of
the Soot Test Pumpe