5.3
Determination of the soot number
:
Fig. 2: Soot comparison chart
6
Taking the sample
NOTE!
To avoid condensation on the filter paper, the measuring head (1) and the probe
should be warmed on the boiler.
6.1
Preparation
Put the used filter paper under the soot com-
parison chart and search the matching seg-
ment.
The soot number of the sample is given by the
number of the matching segment.
Determine the arithmetical mean of three soot
numbers and round it up or down to the next
number.
This rounded mean represents the soot number of
the heating system.
Place the filter paper between the measuring
head (2) and the probe support (5).
Close the measuring heads by pressing the
clamps (3). It is important that the notch pin
engages into the notch of the ryton part.
NOTE!
A few quick pump strokes, previously to the
measurement, increase the operational qualities
of the instrument.
Fix the sampling probe tightly in the flue gas
pipe at the point of the highest temperature.
Use an cone 8 mm Ø.
Taking the sample
EN
21