Herunterladen Inhalt Inhalt Diese Seite drucken

Buzzer; Alarm Led - Deye Spring Se-F12 Bedienungsanleitung

Lfp-batterie
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

6.2 Buzzer

Your equipment is equipped with a buzzer, which will sound a alarm to reminder that you have to
check whether your equipment is in the following situations:
Condition
Alert for 100ms
at intervals of
2s with ALARM
LED flashing
Alert once per
second with the

ALARM LED

flashing
simultaneously
Possible triggers
SOC≤ 5%,not being charged
Inverse connection when
charging
There is MOS adhesion existing
Cell voltage is higher than 3.8V
Discharge/charge temperature is
higher than the valve value.
Charge the battery in time
Check and and then rectify the wire
connection
Contact the service center
Check that sampling line is normal;
Test the cell voltage using a
multimeter;
Inspect the SOH of the battery;
Refer to data record for recharge at
the low current.
Check that there is rapid charge at the
high current or there is a surge on
load ;
Check that there is long-time charge
or over-discharge ;
Check that the temperature of the
environment around the battery ;
Check that the battery is aged or
damaged