5.1 Use of the CC Luxe
The overview below summarizes the information that will be displayed on the CC Luxe.
If the function is not
surrounded by a
,
then it is not active
Current outside temperature
Current indoor temperature
and button for setting the
comfort temperature and
ComfoCool control.
Actual ventilation setting
(programmable
using MAN function)
Automatic (=AUTO)
or manual (=MAN)
ventilation activated
The CC Luxe display is a touch screen. All settings can be accessed, adjusted and
confirmed simply by touching the screen.
If a feature or device is not
registered, the corresponding
buttons and/or symbols will not
be shown.
While the open fire programme
is activated, or when an
ComfoCool is registered, the
supply and exhaust fan cannot
be manually switched off.
If the CC Luxe is not operated
for 30 seconds, it automatically
returns to the main screen. Your
settings will be saved.
The CC Luxe allows the following
functions to be programmed and
displayed:
- Setting the screen;
- Setting the day and time;
- Setting a time delay for a number of
ventilation settings;
- Setting the language;
- Setting a temperature correction;
- Setting temperatures to be displayed;
- Setting the P menus (only by the fitter);
EN 32
ComfoCool (=
OPEN (=
)
afterheater (=
or CLOSE (=
)
and/or ComfoHood (=
the air supply
activated
Check:
System status
and error messages
Heat Recovery
system registered
)
OPEN (=
)
or CLOSE
)
the air exhaust
Wednesday
Cooker hood
Settings
A
GHE
Valve Heat
Recovery open
External 0-10V analog
control active
or bypass CLOSED [=
- Setting a personal ventilation
programme;
- Setting a personal temperature
programme;
- Setting and reading the ventilation
volume;
- Switching the supply and exhaust fan
on/off;
- Setting the comfort temperature;
- Switching the ComfoCool on/off
(optional);
- Switching the ComfoHood on/off
(optional);
A concise explanation of the most
important items in the above listing is
given in the paragraphs below. Anything
not explained can be found in the user
manual.
System settings
The following settings can be made in the
first screen of the system settings menu:
- Screen settings of the CC Luxe;
- Day and time settings of the CC Luxe;
- Time delays.
)
If the function is not
(=
)
surrounded by a
then it is not active
Time and date
Switch ComfoHood
ON (=dark)
or OFF (=light)
To screens where
other settings can be made
Switch automatic or manual
ventilation ON (=dark)
or OFF (=light)
Go to SYSTEM STATUS
screen (for system data
and error messages)
Bypass
[=
]
OPEN
]
,