Herunterladen Diese Seite drucken

Exide MOTION+ PREMIUM SP3 Bedienungsanleitung Seite 6

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9
This mode can be enabled by pressing the pause button for 5 seconds whilst the fault is
displayed. Battery recover mode will then start; once the battery voltage has been recovered
to a normal level a standard charge will be performed.
1.6
Faults / Warnings
In the event of a problem occurring, the charger will display an appropriate fault / warning
code via the charge status indicator. This code will consist of a number of red flashes, as
shown in the tables below, followed by a green flash.
Faults permanently stop charge until they are rectified.
No. of RED flashes
1
2
3
4
5
6
7
8
• Fault Number 1 is critical and will prevent charging.
• Fault 2 is likely to indicate an internal charger fault.
• Faults 3 to 5 occur when a particular stage of charge takes too long. This indicates that
the battery might be at fault or have been over discharged.
• Fault 6 may occur if the charger is in an ambient temperature above 35°C or airflow is
restricted. Charge stops under these conditions until the charger has cooled sufficiently.
• Fault 7 will occur if there is a problem with the internal configuration file
• Fault 8 will occur if the optional safety disconnect system wiring is damaged.
Warnings do not affect the charge procedure.
No. of RED flashes
11
12
Fault
Incorrect battery voltage
Incorrect current control
Bulk timeout
Gassing timeout
Auto-balance timeout
Charger over temperature
Configuration error
Safety disconnect system error
Warning
Sulphated battery
Battery disconnected during charge
6/87
English

Werbung

loading

Verwandte Produkte für Exide MOTION+ PREMIUM SP3

Diese Anleitung auch für:

Motion+ premium sp3+