R S - 2 3 2 C o m m a n d s

Interface configuration:

❙ 9600 baud
❙ 8 data bits
❙ 2 stop bits
❙ no hardware protocol
All interface lines are galvanic coupled to the LISN.
4.3

RS-232 Commands

The LISN interprets the following remote control
commands. Please consider the lower/upper case
letters.
Command
Function
Remote control
R
enabled
Local control
O
Protect. ground line
P
sim. circuit on
Protect. ground line
p
sim. circuit off
(bypass)
EMC test signal of
N
line N
EMC test signal of
n
line L1
Transient limiter off
L
Transient limiter
l
activated
20
Subject to change without notice
Indication
RM-LED
activated
RM-LED
disabled
PE-LED
activated
PE-LED
disabled
N-LED
activated
L1-LED
disabled
OFF-LED
blinking
OFF-LED
disabled

Werbung