Technical Data
Line Impedance Stabilization Network
HM6050-2
All data valid at 23 °C after 30 minutes warm-up.
Frequency Range:
Impedance Characteristics:
Max. Current:
Line Voltage/Frequency:
Artificial Hand:
PE(selectable):
Transient Limiter
Frequency Range:
Transmission Loss:
Connectors
Measurement Output:
Power Supply Socket for DUT:
Artificial Hand:
Line Cord:
Miscellaneous
Operating Temperature:
Power Supply:
Safety Class:
Dimensions(WxHxD):
Weight:
Accessories supplied:
Line cord, Operating manual
10 kHz to 30 MHz
 Z =50 Ω ||(50 µ H+5 Ω ),
Error <20 % under terms of VDE 876T1
16 A
230 V/50...60 Hz, CAT II
220 p F+511 Ω
50 µ H||50 Ω
150 kHz to 30 MHz
10 d B(+1.5/-0.5 d B)
50 Ω BNC
Schuko plug socket for:
HM6050-2D(DEVersion)
HM6050-2K(UKVersion)
HM6050-2S(USVersion)
4 m mbananasocket
Fixed
10°C to 40 °C
HM6050-2D(DEVersion)
230 V ±10 %, 50...60 Hz
HM6050-2K(UKVersion)
230 V ±10 %, 50...60 Hz
HM6050-2S(USVersion)
115 V ±10 %, 50...60 Hz
SafetyclassI(IEC1010-1/VDE0411)
285 x 125 x 380 mm
Approx. 6 kg
1

Important Hints

1.1

Symbols

(1)
(2)
(3)
Symbol 1:
ATTENTION refer to manual
Symbol 2:
DANGER High voltage
Symbol 3:
Protective ground (earth) terminal
Symbol 4:
L1/N – identification of power lines
(Lit, if the power cable connector
is plugged in correctly (phase))
1.2

Unpacking

It is highly recommended to read this operating ma-
nual before using the HM6050-2 . Please check for
completeness of parts while unpacking. Also check
for any mechanical damage or loose parts. In case of
transport damage inform the supplier immediately
and do not operate the instrument.
1.3

Transport

Please keep the carton in case the instrument may re-
quire later shipment for repair. Losses and damages
during transport as a result of improper packaging
are excluded from warranty!
1.4

Storage

Dry indoor storage is required. After exposure to
extreme temperatures, wait 2h before turning the
instrument on.
1.5

Safety

The instrument conforms to VDE 0411/1 safety
standards applicable to measuring instruments and
it left the factory in proper condition according to
this standard. Hence it conforms also to the Euro-
pean standard EN 61010-1 resp. to the international
standard IEC 61010-1. Please observe all warnings
in this manual in order to preserve safety and gua-
rantee operation without any danger to the operator.
According to safety class 1 requirements all parts
of the housing and the chassis are connected to the
safety ground terminal of the power connector. For
safety reasons the instrument must only be operated
from 3 terminal power connectors or via isolation
transformers. In case of doubt the power connector
should be checked according to DIN VDE 0100/610.
Subject to change without notice
I m p o r t a n t H i n t s