Maintenance

Fuse replacement

If you have to replace fuses, ensure that you only use fuses of the same type and rated current (see „Technical data").
It is absolutely impermissible to repair fuses or to bridge the fuse holder.
Pull the mains plug out of the outlet and separate the non-heating appliance plug from the mains connection on
the device.
Carefully prise the fuse holder with a screwdriver out of the mains connection.
Remove the defective fuse and replace it with a fuse of the same type.
Carefully push the fuse holder with the new fuse back into its holder at the mains connection.
Only then may you reconnect the device to the mains and put it into operation again.

Disposal

When the product is no longer usable, dispose of it in accordance with the applicable statutory
regulations.

Technical data

Operating voltage .............................................................. 230V AC/50 Hz
Power consumption ........................................................... 1540W max.
Illuminant ............................................................................ 1500W flash tube LA601
Fuse .................................................................................... T15AL/250V (5x20mm)
DMX protocol ..................................................................... DMX512
DMX channels .................................................................... 2
Dimensions ........................................................................ 445 x 177 x 137mm
Weight ................................................................................ 3.6kg
23