SIP station SIP-WS 800F MD
Dimensions and recommended mounting height
Measuring units in mm (in), not to scale!
Depth: 13 (0.51)
cavity wall mounting: 15 (0.59) ( shadow gap between front panel & wall)
165 (6.5)
Send feedback
We are constantly striving to make our products even better. Follow the link to
the Commend feedback form and let us know what you think.
Handling
Use the original packaging when transporting the device to prevent damage.
Observe the precautions for handling of electrostatic sensitive devices.
Disposal and recycling
This device must not be disposed of together with household waste or commercial waste.
In the EU: The directive 2012/19/EU applies (Waste from Electrical and Electronic Equipment,
WEEE). Worldwide: The country-specific regulations for disposal apply.
Manufacturer's reference
This device complies with the European directives listed below by fulfilling corresponding
standards:
• Electromagnetic compatibility (directive 2014/30/EU)
• The restriction of the use of certain hazardous substances in electrical and electronic
equipment (directive 2011/65/EU)
For technical data and configuration, see the respective manual.
Keep this description in safe custody.
Type: D-BZ-SIPWS8FMD, Version: 1.1/1124
Commend International GmbH, Saalachstraße 51, A-5020 Salzburg – www.commend.com/sip
Extent of supply
• SIP station
• Short reference
• Locking block
• Device identification document
Finished floor
Connection diagram
Alternative
DC–
power supply
DC+
24 VDC (± 2 V)
OUT 2
Expansion
jack (e.g. for
OUT 2
EB2E2AHE)
OUT 1
OUT 1
IP uplink
+ PoE
(e.g. IP camera)
Locking the front panel (example with surface mount box)
Note: The locking of the front panel is also possible at the top face side.
Safety warnings
• This device shall be installed or replaced by trained and qualified personnel only.
• Do not install the device on unstable walls or on surfaces, which cannot support the device's weight.
• Only use recommended tools when installing the device.
• Only accessories that comply with the device's technical specifications shall be used.
• All connected circuits shall fulfil the requirements for Safety Extra Low Voltage (SELV) and Limited
Power Source (LPS) according to IEC/EN 60950-1.
• Use shielded Ethernet cables only.
• Before using the device, ensure all cables are correctly connected and not damaged.
• Disconnect the power supply (PoE or DC) for any maintenance of the device.
• Allow the device to cool down completely before touching parts inside.
• Do not make any unauthorised modifications to the device.
External
loudspeaker module
IN 1
MUTE
IN 2
GND
LINE–
IN 3
GND
LINE+
IP downlink
Handset
(e.g. WSHS 50P-JST)
Screw
Locking block
1. Insert the locking block into the surface mount box or
into the mounting frame of the flush mount box
2. Press on station front panel
3. Screw on the screw via the notch at the bottom face side
of the station front panel
Factory
Reset
button
loading

Inhaltszusammenfassung für Commend SIP-WS 800F MD

  • Seite 2 Verriegelung der Frontplatte (Beispiel mit Aufputzdose) Fertige Fussbodenoberfläche Feedback senden Wir bemühen uns, unsere Produkte noch besser zu machen. Folgen Sie dem Link zum Commend-Feedback-Formular und lassen Sie uns wissen, was Sie denken. Schraube Verriegelungsblock 1. Den Verriegelungsblock in die Aufputzdose bzw. in den Montagerahmen der Unterputzdose einsetzen 2.