2.The cylinder valve should be in OFF position.
3.Make sure the burner valve is in OFF position.
4.Inspect the valve connections, port and regulator assembly. Remove debris and
inspect the hose for damage.
5.When connecting the regulator assembly to the valve, tighten the nut clockwise
by hand until it stops.
Use of a wrench could damage the quick coupling nut and result in a hazardous
situation.
6.Open the cylinder valve fully by turning the valve counterclockwise.
7.Before lighting the oven, use a soap and water solution to check all connections
for leaks.
8.If a leak is found, turn the cylinder valve OFF, and do not use the oven until local
liquid propane dealer can make repairs.
CONNECTING THE LIQUID PROPANE GAS CYLINDER
1.Turn the oven burner valve OFF and make sure the oven is cool.
2.Turn the liquid propane cylinder valve OFF by turning clockwise until it stops.
3.Detach the regulator assembly from the cylinder valve by turning the quick
coupling nut counterclockwise.
4.Place dust cap for cylinder valve outlet whenever the cylinder is not in use.

LEAK TESTING

GENERAL
Although the gas connections of the appliance are leak tested prior to packing and
shipment, a complete test must be performed at the installation site.
Before each use, check all the gas connections for leak testing using the
procedure listed below. If the smell of gas is detected at any time, you should
immediately stop using and check the entire system for leaks.

BEFORE TESTING

Make sure all packing material has been removed from the appliance.
Make a solution of one part liquid detergent and one part water. You will need a