Vulkan LOKPREP LDS-SET-H Betriebsanleitung Seite 16

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

7.4
The digital displayed pressure unit (P-Unit)
can be switched between PSI and BAR by
pressing UP or DOWN key.
EN
7.5
By pressing the UP or DOWN key, the value
for the low pressure alarm-limit (P-Alarm)
can be set. If the input pressure is lower
DE
than the selected limit, the dispensing valve
controller (1) switches to ALARM mode and
no new dispensing is possible.
The recommended value for the low
!
pressure alarm-limit (P-Alarm) is 5.0 BAR
(72.5 PSI).
7.6
Press the SAVE key to save your settings.
7.7
Use the pressure regulator to set the
compressed air pressure to 0.5 bar (7.25
psi).
To change the set pressure, you must
!
pull out the rotary control slightly.
16
Operating Instructions / LOKPREP® Dispensing System LDS-SET-H / LDS-SET-V
LDS-SET-UM-U1-V1.0