5.4
Filter pressure regulator
5.4.1
Assemble the gauge (5) to the filter pressure
regulator (4).
!
Use a few layers of PTFE-tape to seal the
connection.
5.4.2
Mount the mounting bracket (6) on a
suitable surface.
5.4.3
Attach the filter pressure regulator (4) to the
mounting bracket (6).
5.4.4
Make sure the filter pressure regulator (4)
is set to 0 bar by turning the adjustment
knob counterclockwise until the limit. This
ensures that no pressurized air is released
in the next step.
LDS-SET-UM-U1-V1.0
4
6
6
6
4
4
Operating Instructions / LOKPREP® Dispensing System LDS-SET-H / LDS-SET-V
5
11
EN
DE