Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Characteristics - Whirlpool KBT 6424 DO (BI)(T) Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Electrical connection
The electrical safety of this appliance can only be guar-
anteed if the latter is correctly and efficiently earthed,
in compliance with regulations on electrical safety. Al-
ways ensure that this vital safety measure has been
taken. If you have any doubts, call in a qualified techni-
cian to check the electrical system thoroughly.
• The manufacturer denies all responsibility for damage
resulting from a system which has not been earthed
correctly.
Before powering the appliance, check whether the tech-
nical characteristics featured on the appliance data
plate correspond with those of the mains electrical
system.
Check that the current load of the mains supply and of
the power sockets is suitable for the maximum power
of the appliance, indicated on the appliance data plate.
If in doubt, contact a qualified professional.
Disconnect the appliance from the electricity supply
before all operations.
Connect your hob to the electrical system by means of a
junction box: if the appliance is connected permanently
to the mains, an omnipolar circuit breaker, accessible if
necessary, with a minimum contact opening of 3 mm
should be installed.
Valid only for models with a power supply cable for
single-phase connections
Some models are supplied with a single-phase power
supply cable, and should consequently only be connected
to the single-phase mains. Observe the wire colours, as
indicated in the diagram attached.
Electrical connections
Voltage, Frequency
FR-BE-AT-DE-GR-ES-IL-
IT-NZ-PT-GP-CH-MA-LU-
N
L
IE-FI-SE-IS-GB-NL-DK
220-240V - 1+N~ 50Hz
BL
BR
CY-MT-AU-NZ-KW
220-240V - 1+N~ 50Hz
N
L
FR-BE-NO
220-240V - 2 ~ 50Hz
BL
BR
BR=BRUN,BL=BLEU
BR=BRAUN, BL=BLAU
BR=BRUIN, BL=BLAUW
BR=BROWN, BL=BLUE
* Application of the simultaneity coefficient in accordance with
cei 60335-2-6 norm
Valid only for models with a power supply cable for
three-phase connections
Some models are supplied with a three-phase power
supply cable, and should consequently only be con-
nected to the three-phase mains. Observe the wire col-
ours, as indicated in the diagram attached.
Electrical connections
N
L1
L2
BL
BR
N

Technical characteristics

Fuses, Sections
25A *
2,5 mm²
Voltage,
Fuses,
Frequency
Sections
FR-AT-BE-DE-ES-
L3
IL-IS-IT-LU-PT-SE
25 A*
-MA-NZ-CH-DK-N-
2,5 mm²
L
400V3+N~50 Hz
N
Valid only for models without a power supply
cable
Some models are not fitted with a power supply cable, as
the cable should be sized according to the type of electri-
cal connection in use (see connection table below). To
connect the cable, proceed as follows:
Using a screwdriver, prise on the side tabs of the ter-
minal board cover;
Pull open the cover of the terminal board.
To install the cable, proceed as follows:
unscrew the wire clamp screw and the contact screws.
to make the desired electrical connection (see table),
use the jumpers housed inside the box. Position the
power supply cable wires according to the indications
in the table.
once the connections have been made, tighten all the
terminal screws fully.
Fasten the supply cable in place with the clamp and
close the cover of the terminal board.
Electrical connections
1
2
3
4
5
L
N
1
2
3
4
5
L1
L2
1
2
3
4
5
L1
L2
N
1
2
3
4
5
L1
L2
L3
1
2
3
4
5
L1
L2
L3
N
1
2
3
4
5
L1
L2
N1
N2
1
2
3
4
5
L
N
* Application of the simultaneity coefficient in accordance with
cei 60335-2-6 norm
14
Fuses,
Voltage, Frequency
Sections
FR-AT-BE-DE-GP-ES--
IE-IL-IS-IT-LU-
25 A*
RE-FI-GB-GR-PT-SE--
2,5 mm²
MA-NZ
220-240V-1+N~50 Hz
FR-BE-NO
25 A*
2,5 mm²
220-240V-2~50/60 Hz
FR-BE-CH-DE-AT-ES--
IL-IT-NZ-PT-
16 A*
MA- LU-SE-IS-NL
1,5 mm²
400V2-N~50 Hz
FR-BE-NO
16 A*
1,5 mm²
220-240V3~50 Hz
FR-AT-BE-DE-ES-
IL-IS-IT-LU-PT-SE
16 A*
-MA-NZ-CH-DK-NL
1,5 mm²
400V3+N~50 Hz
NL
16 A*
1,5 mm²
220-240V2+2-N~50 Hz
CY-AU-NZ-KW-MT
25 A*
2,5 mm²
220-240V-1+N~50 Hz

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis