DCF Immersion Troubleshooting

Fluid leakage from
The valve is not installed correctly.
the container.
Fluid level window.
Fluid at the secon-
Leakage through the filter or bolts.
dary side of the filter.
The ball valve is clogged.
Fluid cannot be
drained.
Low flow.
Incorrect settings at suction source.
The hose is damaged.
The fine filter is clogged Fig. 1 - G.
The demisters filter is clogged Fig. 1 - E.
The strainer basket is full Fig. 1 - D.
Air leakage.
Fluid level low.
High airflow.
Too long intervals between level checks.
Leakage.
Other
High level of oil and material at filter or demister
top.
DCF immersion
Remove the valve. Use thread sealant and refit the valve.
Tighten the screws, change the gasket.
Replace filter or seal at the bolts.
If clogged, loosen and check strainer basket carefully for leak-
age.
Adjust the suction source.
Replace the hose.
Clean the filters according to the filter cleaning procedures.
Clean the filters according to the filter cleaning procedures.
Empty the strainer basket.
When the unit is running. Check if air is leaking in from an
opening.
Check the suction source
Check the fluid level more frequently.
Check the unit for leaks.
Check the unit for leaks.
Check the seal at the demister.