CONTROLLING THE PRODUCT VIA BLUETOOTH (T5)
It is a protocol for the interconnection of electronic devices
by means of radio waves instead of cables (for pairing, see
the "Assembly and Use" manual of the Hob).
CONTROLLING THE PRODUCT VIA Wi-Fi (T6)
This feature allows the product to be controlled from a
mobile device, even when away from home. To use the
product via Wi-Fi, it is necessary to download the Elica
Connect App and follow the instructions given.
- Wi-Fi Configuration:
Follow the instructions provided in the Elica Connect App
for the Wi-Fi configuration. During the configuration
procedure, the LED of key T6 will light up indicating the
connectivity status (see the Wi-Fi status table below).
To interrupt or reactivate the Wi-Fi configuration procedure,
press T6 for 6 seconds.
- Wi-Fi configuration reset:
This operation is used to reset the product to the factory
configuration.
Press T6 for 6 seconds; the status will be "not configured"
and the LED of key T6 will go out.
Note: The password and all other settings made from the
Elica Connect App will be reset and will need to be set
again.
- Wi-Fi On/Off:
after the configuration, the Wi-Fi can be switched on / off.
Press T6 for 2 seconds.
Note: switching off the Wi-Fi with this procedure does not
result in the loss of the previously saved parameters.
Wi-Fi status table
L6 LED
Wi-Fi Status
Light off
Wi-Fi not configured or off
Entering the router credentials.
Orange light fla-
Attention: there is a maximum time
shing fast
limit of 5 minutes to enter the cre-
dentials.
Attempt to connect to the Wi-Fi rou-
Steady orange light
ter
White light flashing
Attempt to connect to the Elica
slowly
Cloud
White light on stea-
Wi-Fi connected
dy
Command received from Elica
White light on with
Cloud App: motor on or light on,
short flashing light
etc.
Filter saturation indicator
The hood indicates when maintenance is needed for the
filters.
Grease filter alarm (every 40 hours of use
approximately):
- with the hood switched off, by pressing any speed, the
keys T1+T2 light up for 10 seconds, indicating
maintenance of the grease filters.
- After carrying out maintenance on the grease filters, it is
necessary to reset by pressing keys T1+T2 for 2 seconds
while the alarm is displayed.
- The reset operation is confirmed if the LEDs of keys T1-
T2 flash quickly and then go out.
To deactivate the grease Filter Alarm function, proceed
as follows:
This alarm is normally active; to deactivate it, perform this
procedure:
with the hood switched off, press and hold keys T1-T2 -T3
at the same time: LEDs T1 T2 and T3 will light up with
different intensities from bright to soft; you will enter the
management menu of the grease Filter alarm, to
deactivate it press keys T1 - T2 at the same time for 2
seconds.
Please note! The function is deactivated if T2 has the LED
with a soft light; if the light of LED T2 is bright, the
operation must be repeated.
To reactivate the grease Filter Alarm function, repeat the
operation.
Activated carbon odour Filter Alarm (every 160 hours
of use approximately):
- with the hood switched off, by pressing any speed, the
keys T1+T3 light up for 10 seconds, indicating
maintenance of the activated carbon filters.
- After carrying out maintenance on the activated carbon
filters, it is necessary to reset by pressing keys T1+T3 for
2 seconds while the alarm is displayed.
- The reset operation is confirmed if the LEDs of keys T1-
T3 flash quickly and then go out.
Activation of activated carbon odour Filter Saturation
alarm.
This alarm is normally deactivated.
To activate it, proceed as follows:
with the hood switched off, press and hold keys T1-T2 -T3
at the same time: LEDs T1 T2 and T3 will light up with
different intensities from bright to soft; you will enter the
activation menu of the activated carbon odour filter
saturation indicator function, to activate it press keys T1 -
T3 at the same time for 2 seconds.
Please note! The function is active if T3 has the LED with
a bright light; if the light of LED T3 is soft, the operation
must be repeated.
- To deactivate the activated carbon odour Filter
Saturation function, repeat the operation.
12