Operating Conditions
Maximum water pressure: 70 psi, or a pressure regulator (Model #APR70) is required if there
is high water pressure or water hammer.
Minimum water pressure: 30 psi, or a booster pump is needed to improve RO e ciency.
Install this RO system where it is protected from hot/cold weather and direct sunlight. Avoid
hitting, dropping, or dragging as they may cause cracks and leaks.
Water Treatment Process
5-Stage System:
Source Water → PP Filter → GAC Filter → CTO Filter → RO Membrane → Post Taste-polishing
Activated Carbon → Puri ed water
6-Stage System:
Source Water → PP Filter → GAC Filter → CTO Filter → RO Membrane → Post Taste-polishing
Activated Carbon → Remineralization Alkaline / UV → Puri ed water
7-Stage System:
Source Water → PP Filter → GAC Filter → CTO Filter → RO Membrane → Post Taste-polishing
Activated Carbon → Remineralization Alkaline → UV → Puri ed water
Filtration Performance
Stage
1
Polypropylene (PP)
st
2
Granular Activated
nd
Carbon (GAC)
3
Carbon Block (CTO)
rd
4
Reverse Osmosis (RO)
th
5
Post Activated Carbon
th
6
/7
th
th
Ultraviolet (UV)
Product Features
Parameter
Minimum Inlet Water Pressure
Maximum Inlet Water Pressure
Inlet Water Temperature
Maximum TDS
Filter
Removes sediments, dust, dirt, sand, silt, rust, and particles.
Removes chlorine, taste, odors, cloudiness, and colors.
Further improves the smell and taste of the water.
Removes up to 99% of contaminants, such as lead, chlorine,
Membrane
uoride, arsenic, hormones, asbestos, calcium, sodium, iron, etc.
Removes any possible residual taste and odors from the tank.
Alkaline
Adds back essential minerals while enhancing the water taste.
Removes waterborne contaminants.
Speci cation
30 psi
70 psi
40-100°F
750 ppm
Purpose