Herunterladen Diese Seite drucken

HomeMatic IP HmIP-SWSD-2 Montage- Und Bedienungsanleitung Seite 48

Rauchwarnmelder mit q-label

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation
6.1
Function test
Once the smoke detector has been installed and added,
you must perform a function test. You should also carry
out a function test once a year after installation to ensure
correct functioning.
To perform the function test, proceed as follows:
Briefly press the control button (D) on the device
once (< 4 s).
If the alarm tone sounds 3 times, the device's LED
(C) flashes red, and the emergency lighting (G)
lights up for the duration of the function test, the
smoke detector is working correctly.
If no alarm sound is heard or no optical signal is
visible, the device is defective and must be re-
placed.
After the function test, smoke detection is deacti-
vated for 10 minutes. During this time, no alarm
can be triggered.
6.2
Communication test
The correct integration of the smoke detector into a
wireless network and its error-free communication
with other smoke detectors can be tested by having the
smoke detector send a radio test signal. To generate the
radio test signal, proceed as follows:
48