Installing the OPT/i CU Filter mounting / Duo in
the CU 800i
Preparatory
1
work
2
3
4
5
Installing the
1
OPT/i CU Filter
mounting / Duo
in the CU 800i
Remove the two blanking covers
3
Cut the hoses to length
Disconnect the cooling unit from all system components
(see cooling unit Operating Instructions)
Remove the six TX25 screws on the side panels of the device
Remove the side panels
Remove the five TX25 screws on the cover
Remove the cover
1
2
630 mm
3
1
1
2
2
2
Insert the connections from the inside to the
outside
Secure the connections with plastic nuts, bot-
tom = red, top = black, 21 mm
4
2
3
Disconnect the return hose from the front and
from the cooler