ENGLISH
-
Set the desired temperature by pressing the increase and decrease buttons. The setting
range is 16 to 30 °C. Each time you press the increase or decrease button, the temperature
will go up or down by 1 °C.
-
Press the fan speed button to select the desired speed, you can choose from a range of 7
speeds or the Turbo function.
-
Press the SWING button to activate or deactivate the left-right oscillation function.
-
Automatic fan speed: "Tr" represents the room temperature and "Ts" the set temperature.
-
When Tr-Ts is equal to or above 3 °C, the fan shall operate at maximum speed.
-
When Tr-Ts + 1 °C is less than or equal to + 3 ºC, but not less than 1 ºC, the fan shall operate
at medium speed. When Tr-Ts is less than 1 °C, the fan shall operate at the lowest speed.
-
You can change the fan speed from lower to higher without waiting, unlike from higher to
lower (you will have to wait 3 minutes for it to be set).
Dehumidification mode (DRY)
-
Press the mode button to select the Dehumidification mode. The corresponding indicator
light will light up.
-
The set temperature is the same as in Cooling mode.
-
The fan speed cannot be adjusted in this mode.
-
Press the SWING button to activate or deactivate the left-right oscillation function.
Fan mode (FAN)
-
Press the mode button to select the Fan mode. The corresponding indicator light will light
up.
-
Press the speed button to select the desired fan speed. You can choose between 7 speeds.
-
Press the SWING button to activate or deactivate the left-right oscillation function.
-
Automatic speed in Fan mode: when Tr is higher than 27 °C, the fan will operate at maximum
speed. When Tr is less than or equal to 27 °C, the fan will operate at medium speed. When Tr
is less than or equal to 24 °C, the fan will operate at the lowest speed.
-
The fan speed changes from lower to higher without waiting, unlike when it changes from
higher to lower.
SLEEP function
-
Press the SLEEP function button on the remote control to activate this function. The
temperature will increase (Cooling mode) or decrease (Heating mode) by 1 °C per hour
during the first 2 hours of operation. After this time, the air conditioner will maintain that
temperature for 6 hours, and then it will automatically switch off. This means that the
SLEEP function lasts for 8 hours and then the appliance switches off automatically. This
function is only compatible with Cooling mode and Heating mode (if the model features
Heating mode).
-
If the fan was running at a high speed, activating this function will automatically decrease
it to a medium speed. On the other hand, if the fan was already running at medium speed,
68
WINDOWCLIMA 9000 INVERTER
the speed will decrease by one level every half hour until it reaches the lowest speed. The
air conditioner will maintain this speed until it automatically switches off after the preset
time has elapsed.
Warning: to deactivate or cancel the SLEEP function automatically, press the Turbo, fan, or
mode button.
Fresh air function
-
Press the mode button on the remote control for 3 seconds to activate or deactivate the
Fresh Air function.
-
This function allows fresh air from outside to enter the room.
-
Before activating the function, manually open the fresh air inlet cover on the right side of
the air conditioner body as shown below:
Fig. 6 and fig. 7
4. CLEANING AND MAINTENANCE
Before cleaning or servicing the appliance, switch it off and unplug it from the mains socket.
Cleaning the housing
1.
Use a soft, damp cloth to clean the outer surface. Do not use chemicals such as benzene,
alcohol, or petrol. Failure to do so may damage the air conditioner housing or even damage the
entire air conditioner.
2.
Cleaning the filter
It is normal for dust to clog the filter. To ensure proper operation of the air conditioner, clean
the filter every 2 weeks.
Fig. 8
1.
Press the grille tab by hand to open it, rotate the air inlet grille, and then remove the dust
filter from inside the grille.
(Caution: the air inlet grille can only be opened by 7 or 8 degrees, do not exert too much force
to avoid breaking it).
2.
Immerse the filter in lukewarm water (approx. 40 °C) with neutral soap. Rinse it and allow
it to dry in a cool, dry place before putting it back in place.
Tank emptying
3.
When the full-tank indicator light lights up, the appliance will stop operating. When this
happens, it will be necessary to drain the excess condensed water from the interior. To do this,
remove the inner or outer drain hose.
ENGLISH
69
WINDOWCLIMA 9000 INVERTER