8 Protective Circuit
The amplifier is equipped with a protective cir
cuit against overheating, overload and short
circuit at the speaker outputs . In case of over
heating, the LED PROTECT (5) will light up;
in case of overload, short circuit or another
defect, the LED FAULT will additionally light
up . In any case, the amplifier will be muted .
If one of these LEDs light up, switch off the
amplifier and have the fault eliminated by
skilled personnel .
If the fault detection module PA6FD
(chapter 4 .1) is not installed, set DIP switch
No . 2 (13) on the rear side of the amplifier to
the lower position ON, otherwise the protec
tive circuit will respond .
9 Specifications
Rated power . . . . . . . . 960 W
THD: . . . . . . . . . . . . . . < 0 .4 %
Output voltage /
output impedance: . . . 100 V / 10 Ω
85 V / 7 .2 Ω
75 V / 5 .6 Ω
Inputs
PGM INPUT: . . . . . . . 0 .775 V / 60 kΩ
PRIORITY INPUT: . . . . 0 .775 V / 60 kΩ
SLAVE INPUT: . . . . . . 100 V
Frequency range: . . . . 35 – 20 000 Hz, −3 dB
S / N ratio: . . . . . . . . . . > 100 dB (A weighted)
Highpass filter: . . . . . . 400 Hz, 6 dB / octave
Power supply
Mains voltage: . . . . . ~ 230 V / 50 Hz
Power consumption: . 2600 VA
Emergency
power supply: . . . . . . ⎓ 24 V / 80 A
Ambient temperature: 0 – 40 °C
Dimensions: . . . . . . . . 482 × 133 × 374 mm
(W × H × D)
Rack units: . . . . . . . . . 3 U
Weight: . . . . . . . . . . . 25 kg
Subject to technical modification .
All rights reserved by MONACOR
No part of this instruction manual may be reproduced in any form or by any means for any commercial use.
®
INTERNATIONAL GmbH & Co. KG.
11