Herunterladen Inhalt Inhalt Diese Seite drucken

Dmx-Protocol; Analog Controller; Cleaning And Maintenance - EuroLite 52201123 Bedienungsanleitung

Led power strobe cob dmx
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DMX-Protocol

Channel
DMX Value Characteristic
1
2

Analog controller

The device must be in DMX-mode in order to control it via an analog controller. Press the MODE button until
the display shows Add.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The protective shield has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
There are no serviceable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
0-255
Flash-rate
0-255
Brightness
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
CAUTION!
22/23