EN
4 - PROGRAMMING
4.1 Description of the programming buttons
Buttons
Function
- Triggers auto-programming
- Memorising/clearing the remote controls
- Modifying the value of a setting
- Using forced operating mode
- Selecting a setting
I n d i c a t o r
- Parameter indicator light selected
light A
I n d i c a t o r
- Parameter value indicator light
light B
- Fault indicator light
4.2 Auto-programming - Fig. 15
[1].
- Release the button to stop the movement.
direction.
[2].
[3].
The door performs a complete Opening-Closing cycle.
interrupted if any of the buttons is pressed.
It is possible to access auto-programming mode at any moment including when
the auto-programming cycle has already been completed.
Note: The remote controls supplied in the kit have already been
memorised.
At the end of installation, it is essential to check that the obstacle
detection complies with appendix A of standard EN 12 453.
4.3 Locking access to the parameters (button A) - Fig.
16
- The parameters menu (button A) is locked.
Once installation is complete, the parameters menu must always be
locked to ensure the safety of users.
Failure to follow this instruction may result in serious injury, e.g. due to
crushing by the gate.
At this stage of the installation, the Dexxo Compact RTS drive is
ready to operate.
5
Indicator light key
off
WARNING
WARNING
5 - OPERATING TEST
5.1 Using the remote controls - Fig. 17
5.2 Obstacle detection operation - Fig. 18 and 19
(Fig. 19).
Check that the obstacle detection function works when the door encounters a
50 mm high obstacle on the ground.
5.3 Integrated lighting operation
The lighting comes on each time the drive is switched on. When the door stops
the lighting to be lit constantly which may result in the light being switched off
automatically due to thermal protection.
5.4 User training
All users must be trained on how to safely use this door (standard use and
locking principle) and on the mandatory periodic checks.
6 - CONNECTING ADDITIONAL DEVICES
6.1 Description of the different additional devices -
Fig. 20
No.
Description
1
Orange light
2
Wired code keypad
3
4
Aerial
5
Battery
6
Photoelectric cells
6.2 Electrical connection of the additional devices-
Fig. 20 to 23
Switch off the electrical supply to the motor before performing any operation on
the additional devices.
General electrical diagram (Fig. 20)
Photoelectric cells (Fig. 21)
and 2.
Solar kit (Fig. 22)
Activate solar mode by adjusting the motor power supply type (see below).
Wired code keypad (Fig. 23)
DEXXO COMPACT RTS
(Fig. 18).
©
Copyright