RZ_Autopump-Set_985088-01.qxp_Text_EN__Autopump 13.09.24 12:00 Seite 21
 The integrated electric AutoPump automatically generates the required operating
pressure in the sprayer and regulates it automatically during operation.
Applies to manual pumping:
Yellow marking:
You are working with the optimum
spray pressure.
7
Shutting down
7.1 Emptying & Cleaning >>
WARNING
safety instructions in this manual. Observe applicable laws and the specifications of the
agent manufacturers when disposing of residual quantities.
 Switch off the device. Initially vent the standing container fully by pulling on the piston-
type pressure gauge with the built-in safety valve "L" and completely releasing the air.
 Now unscrew the pump carefully, at first only a few turns of the thread in a counter-clock-
wise direction so that any residual compressed air in the container can escape. Only now
unscrew and remove the pump completely.
 Do NOT pour the residual quantity into the sink, but pour it through the filling hole into a
suitable canister.
7.2 Remove rechargeable batteries / batteries >>
 Switch off the device. Initially vent the standing container fully by pulling on the piston-
type pressure gauge with the built-in safety valve "L" and completely releasing the air.
 Now unscrew the pump carefully, at first only a few turns of the thread in a counter-clock-
wise direction so that any residual compressed air in the container can escape. Only now
unscrew and remove the pump completely.
 Now disconnect the pump from the battery/rechargeable battery compartment "C" and
remove the batteries/rechargeable batteries.
7.3 Maintenance >>
 Observe the national regulations concerning occupational safety which apply to the place
of operation as well as the applicable national regulations for operations.
 Only use original GLORIA spare parts for repairs. (see GLORIA spare parts shop
https://shop.gloriagarten.de).
 Repairs must only be carried out by a GLORIA service point.
 Regularly coat the seals with GLORIA silicone grease.
 Further accessories can be found at www.gloriagarten.de
CAUTION
reach of children.
Empty and clean the device as in Chapter 7.1.
Figures
Danger to health due to escaping spraying agents! Pay attention to the
30
28
Figures
You must therefore store the device and the spraying agents out of the
Red marking: If you exceed the
optimum spraying pressure, do not
continue to SPRAY, vent the device.
19
23
24
Figures
21
27

Werbung

loading

Diese Anleitung auch für:

000910.000