Release the flow button
-
if the value is above or below the specified flow rate, check the welding torch for
damage
-
if necessary, repair the welding torch
-
repeat the flow test after the torch has been repaired
NOTE! For the specified gas flow rates, refer to the "Welding torch flow rates"
service test schedule (PP-SER-2001). The "Welding torch flow rates" service test
schedule (PP-SER-2001) is available from the DownloadCenter.
Screw the plasma gas hose (1) of the
1
hosepack onto the adapter attachment
(2)
Press and hold the flow button on the
2
adapter
-
The flow rate is measured
Note the value shown on the testbox
3
display and compare with the specified
flow rate