Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Noise; Troubleshooting - Powerplus Powair0312 Bedienungsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
11

TECHNICAL DATA

Model
Activation mode
Max. allowable pressure
Operating pressure
Air inlet size
Avg. air consumption
Recommended lubricant
Nail capacity
12

NOISE

Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
Acoustic power level LwA
ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).
aw (Vibration)
13

TROUBLESHOOTING

SYMPTOM
Air leak
near top of tool or in
trigger area
Air leak near bottom
of tool.
Air leak between body
and cylinder cap.
Blade driving fastener
too deep.
Copyright © 2024 VARO
POWAIR0312
POWAIR0312
Single sequential action
120PSI(8.3 bar)
60-100PSI(4-7bar)
¼"
51 l/min
White mineral oil
100pcs
87 dB(A)
100 dB(A)
1.9 m/s²
PROBLEM
O-ring in trigger valve is
damaged.
Trigger valve head are
damage.
Trigger valve stem, seal or
O-ring are damaged.
Loose screws.
Worn or damaged O-rings
or bumper.
Loose screws.
Worn or damaged O-rings
or seals.
Worn bumper.
Air pressure is too high.
P a g e
K = 0.8 m/s²
SOLUTIONS
Check and replace O-ring.
Check and replace.
Check and replace trigger
valve stem, seal or O-ring
Tighten screws.
Check and replace O-rings
or bumper.
Tighten screw.
Check and replace O-rings
or bumper.
Replace bumper.
Adjust the air pressure.
| 9
EN
www.varo.com
Inhaltsverzeichnis
loading

Inhaltsverzeichnis