Herunterladen Inhalt Inhalt Diese Seite drucken

Powerplus POWAIR0312 Bedienungsanleitung Seite 37

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
▪ Air hose minimum working pressure rating of 150 psi (10.3 BAR) or 150% of the
maximum pressure produced in the system is absolutely necessary. (fig 8)
▪ The tool and air supply hose must have a hose coupling such that all pressure is
removed from the tool when the coupling Joint is disconnected. (fig 9)
▪ Use only compressed air coming through 3 pieces set. (fig 10)
▪ Never load fastener before tool connected to air supply (fig 11)
▪ Never use tool if safety element, trigger or springs have become inoperative, missing or
damaged, It is hazardous to remove safety element, trigger or spring. (fig 12)
▪ Before using this tool, make sure trigger, screw and cap are securely tightened. (fig 13)
▪ Do not modify tool without authorization. (fig 14)
▪ Disconnect tool from air whenever the tool stops working (fig15)
▪ Keep the tool pointed away from yourself and others. (fig 16)
▪ Fire fasteners into work surface only, never into materials too hard to penetrate. (fig 17)
▪ Do not drive fasteners on top of other fasteners. Tool fired in an inclined angle is also
forbidden. (fig 18)
▪ Do not push safety element on work surface until a second fastener is desired (fig 19)
▪ Do not drive fasteners close to the edge of the work surface. The work piece is likely to
split and the fastener could fly free and hit someone. (fig 20)
▪ Do not load fasteners with trigger or safety element depressed. (fig 21)
▪ Do not use tool without Danger label on tool. (fig 22)
▪ Never use a tool that leaks air or needs repair. (fig 23)
▪ Be sure you are in a balanced position when using or handling the tool (fig 24)
▪ Operate tool at recommended pressure of 4-8 bar
8
TOOL USE
1.
Read "Safety Warnings" before using tool
2.
Push magazine lock lever and slide upper magazine to
open magazine.
3.
Place strip of nails or staples into the magazine with
the point resting on the fastener guide. Do not load
with trigger depressed.
4.
Push upper magazine back until magazine lock
latches.
Copyright © 2024 VARO
POWAIR0312
P a g e
| 6
EN
www.varo.com
Inhaltsverzeichnis
loading

Inhaltsverzeichnis