Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

OPERATION

After you connected the effect to the mains, the EUROLITE LED SDR-8 starts running. During the Reset, the
motors are trimmed and the device is ready for use afterwards.

Stand-alone operation

In the Stand-alone mode, the LED SDR-8 can be used without controller.
Disconnect the LED SDR-8 from the controller and call the internal program. Please refer to the instructions
under Control Board.

Master/Slave operation

The master/slave operation enables that several devices can be synchronized and controlled by one master-
device.
On the front panel of the device you can find an XLR-jack (DMX Out) and an XLR-plug (DMX In), which can
be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master device and controls all
other slave devices, which are to be connected to the master device via a DMX cable. Connect the DMX
OUT-jack with the DMX IN-plug of the next device.
Set "Auto" or "Soun" - for the master device, as described in chapter Control Board. Set "SL1" or "SL2" for all
slave devices.
International
L
N
26/32