Transmitter parts
EA00043D/06/A2/13.10
71124463
Determining the correct spare part set
This method is used merely to determine whether the spare part set is suitable for the measuring device. Other conclusions drawn from the table are not applicable.
1. Read the order code from the nameplate on the measuring device and enter it in the empty fields below.
2. Select the order number of the spare part set in the table below.
3. Check the fields after the order number selected against the highlighted items in the order code.
4. If each field after the selected order number contains a digit or letter from the order code, the spare part set can be used for the measuring device
(* = no restriction).
!
Note! The number of the spare part set can differ from the material number of the spare part it contains!
The order number of the relevant spare part set can be established by entering the material number of the spare part in the spare parts finder.
We recommend that the Installation Instructions be kept with the packaging at all times.
Order No., Original Spare Part Set
Kit display Prowirl 72, 73, Prosonic Flow 92F
with keyboard, HART, 12 languages
50103472
Language: EN, DE, FR, ES, IT, NL, NO, SV, FI, PT, PL, CS
1 × display-module with keyboard complete
Kit display Prowirl 72, 73, Prosonic Flow 92F
without keyboard complete, FF/PA, 12 languages
50103473
Language: EN, DE, FR, ES, IT, NL, NO, SV, FI, PT, PL, CS
1 × display-module without keyboard complete
Kit amplifier Prowirl 72 Ex
50103475
1 × print amplifier V04 Prowirl 72 Ex
Kit I/O-board Prowirl 72, 73, HART Exi
50103476
1 × Comodul C08 2-wire HART EEx-i
1 × terminal connection 2pol
Kit I/O-board Prowirl 72, 73, HART/pulse Exi
1 × comodul C08 2-wire HART/P EEx-i
50103477
1 × terminal connection 2pol
1 × terminal connection 2pol
Kit I/O-board Prowirl 72, 73 PROFIBUS PA Exi
50103478
1 × Comodul C09 2-wire EEx-i
1 × terminal connection 2pol
Kit circuit board Prowirl 72, 73 field housing
50103528
1 × PCB fastening bracket Prowirl
Kit display carrier complete Prowirl 72, 73
Prosonic Flow 92F field housing
1 × display holder
1 × cover electronic
50103529
1 × cover plate connection compartment
2 × screw M4 × 14/4.5
3 × washer M4
1 × screw M4 × 12/4.5
Kit amplifier Prowirl 73 Ex
50106027
1 × print amplifier V04 Prowirl 73 Ex
Kit I/O-board Prowirl 72, 73, HART Exd
50106382
1 × comodul C11 2-wire Hart EEx-d
1 × terminal connection 2pol
Kit I/O-board Prowirl 72, 73 PROFIBUS PA Exd
50106383
1 × comodul C09 2-wire EEx-d
Kit I/O-board Prowirl 72, 73 HART/pulse Exd
1 × comodul C11 2-wire HART/Puls EEx-d
50106384
1 × terminal connection 2pol
1 × terminal connection 2pol
Kit connection board Prowirl 72, 73 PROFIBUS PA/FF Exd
50106385
1 × comodul C12 PA/FF I EEx-d
1 × terminal connection 2pol
Kit I/O-board Prowirl 72, 73 FOUNDATION Fieldbus Exi
50107084
1 × comodul C09 2-wire FF EEx-i
1 × terminal connection 2pol
Kit I/O-board PW72, 73 FOUNDATION Fieldbus Exd
50107085
1 × comodul C09 2-wire FF EEx-d
Kit terminal block Prowirl 72, 73, Prosonic Flow 92F
50108141
1 × terminal connection 2pol
1 × terminal connection 2pol
1
Prowirl
7
Prosonic Flow
9 2 F * * – * * * * *
2
3
4
5
6
7
* * – * * * * * *
7
2, 3
*
9
2
F
7
2, 3
*
9
2
F
7
2
*
A, C, D, F, G, H, N, P, S, U, W, 1, 2, 3, 7
7
2, 3
*
A, D, G, H, N, S, 1, 2, 7
7
2, 3
*
A, D, G, H, N, S, 1, 2, 7
7
2, 3
*
A, D, G, H, N, S, 1, 2, 7
7
2, 3
*
A, C, D, F, G, H, N, P, S, U, W, 1, 2, 3, 7
7
2, 3
*
A, C, D, F, G, H, N, P, S, U, W, 1, 2, 3, 7
9
2
F
A, C, D, H, N, P, F, G, U, W, 1, 2, 3
7
3
*
A, C, D, F, G, H, N, P, S, U, W, 1, 2, 3, 7
7
2, 3
*
7
2, 3
*
7
2, 3
*
7
2, 3
*
7
2, 3
*
A, D, G, H, N, S, 1, 2, 7
7
2, 3
*
7
2, 3
*
9
2
F
8
9
10
11
12
13
* * *
*
4
*
4
*
6
*
6
*
*
*
*
*
*
*
*
C, F, P, U, W, 3
*
C, F, P, U, W, 3
*
C, F, P, U, W, 3
*
C, F, P, U, W, 3
*
*
C, F, P, U, W, 3
*
*
*
*
*
14
15
16
17
18
* *
*
*
A, W
A, W
H, K
H, K
*
W
A
H
*
*
*
*
W
H
A
H, K
K
K
A, H, K, W
A, H, K, W

Werbung

loading

Inhaltszusammenfassung für Endress+Hauser Prosonic Flow 92

  • Seite 1 Installation Instructions Prowirl 72, 73, Prosonic Flow 92 Transmitter parts EA00043D/06/A2/13.10 71124463 Determining the correct spare part set This method is used merely to determine whether the spare part set is suitable for the measuring device. Other conclusions drawn from the table are not applicable.
  • Seite 2 71026986, 71026987 1 = Trained specialist on the customer side, 2 = Service technician authorized by Endress+Hauser, 3 = Endress+Hauser Flowtec AG (send device) * It is recommended that devices with a design approval be repaired by skilled professionals who have been trained by E+H.
  • Seite 3 Prowirl 72, 73, Prosonic Flow 92 Transmitter parts Safety Instructions • Comply with national regulations governing mounting, electrical • After removing the electronics cover, there is a risk of electric shock installation, commissioning, maintenance and repair procedures. as shock protection is removed! •...
  • Seite 4 Prowirl 72, 73, Prosonic Flow 92 Transmitter parts 8. Unplug ribbon-cable connector (6) from the amplifier board, release it from 3 Saving device data the cable retainer, and remove display module (3). Prosonic Flow 92: 9. Release securing screw (7) and fold down cover.
  • Seite 5 Einbauanleitung Prowirl 72, 73, Prosonic Flow 92 Messumformerteile EA00043D/06/A2/13.10 71124463 Ermitteln des zulässigen Ersatzteilsets Diese Methode dient nur zur Überprüfung, ob Ersatzteilset und Messgerät zueinander passen. Andere aus der Tabelle gezogene Schlussfolgerungen sind nicht gültig. 1. Bestellcode auf dem Typenschild des Messgeräts ablesen und unten in die leeren Felder eintragen.
  • Seite 6 71026986, 71026987 1 = Ausgebildete Fachkraft des Kunden, 2 = von Endress+Hauser autorisierter Servicetechniker, 3 = Endress+Hauser Flowtec AG (Gerät einsenden) * Es wird empfohlen, Reparaturen welche an Geräten mit Bauartzulassung vorgenommen werden, von ausgebildeten Fachleuten durchführen zu lassen, die von E+H geschult wurden.
  • Seite 7 Prowirl 72, 73, Prosonic Flow 92 Messumformerteile Sicherheitshinweise • Nationale Vorschriften bezüglich der Montage, elektrischen • Nach Entfernen der Elektronikabdeckung: Stromschlaggefahr durch Installation, Inbetriebnahme, Wartung und Reparatur einhalten. aufgehobenen Berührungsschutz! • Anforderungen an das Fachpersonal für Montage, elektrische Messgerät ausschalten, bevor interne Abdeckungen entfernt werden.
  • Seite 8: Gerätedaten Sichern

    Prowirl 72, 73, Prosonic Flow 92 Messumformerteile 7. Kunststoffabdeckung (4) hochklappen und Signalkabelstecker (5) aus der 3 Gerätedaten sichern Messverstärkerplatine ziehen. Prosonic Flow 92: 8. Flachbandkabelstecker (6) aus der Messverstärkerplatine ziehen und aus der Parameter des Messumformers auf das T-DAT (11) sichern mit Hilfe der Kabelhalterung lösen und Anzeigemodul (3) entfernen.

Diese Anleitung auch für:

Prowirl73Prowirl 72