Herunterladen Inhalt Inhalt Diese Seite drucken
Endress+Hauser Prowirl 73 Einbauanleitung
Vorschau ausblenden Andere Handbücher für Prowirl 73:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation Instruction
Installing sensor parts
Prowirl 72, 73, Prosonic Flow 92 F
EA00042D/06/A2/14.12
71191695
Instruction is valid for the following spare part sets
Order No Device component
Kit gasket Prowirl 77, 72, 73
50093513
1 × gasket 25.0/20 × 0.76 mm, (1.0/0.79 × 0.03 inch) Kalrez
Kit 10 gaskets Prowirl 77, 72, 73
50093514
10 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Viton
Kit 10 gasket Prowirl 70, 72
50093627
10 × gasket flat 17.0/9.5 × 1.0 mm (0.67/0.37 × 0.04 inch)
Grafoil
Kit 10 gasket Prowirl 77, 72, 73
50095114
10 × gasket 25.0/20 × 0.8 mm (1.0/0.79 × 0.03 inch) Gylon
Kit preamplifier Prowirl 72, 73 
50103474
1 × preamplifier V05 Prowirl
Kit DSC-sensor Prowirl 72 standard
Basic version, 316L, –40 to +260 °C, (–40 to +500 °F)
1 × sensor Prowirl 72 complete, 4 × screw M5 × 12
50103479
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Sigraflex
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Viton
1 × gaslet 25.0/20 × 0.8 mm (1.0/0.79 × 0.03 inch) Gylon
Kit DSC-sensor Prowirl 72 standard 3.1
Basic version, 316L, –40 to +260 °C, (–40 to +500 °F)
1 × Sensor Prowirl 72 complete 3.1, 4 × screw M5 × 12
50103480
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Sigraflex Z
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Viton
1 × gasket 25.0/20 × 0.8 mm (1.0/0.79 × 0.03 inch) Gylon
Kit DSC-sensor Prowirl 72 high-/low temperature 3.1
High/low temp., 316L, –200 to +400 °C (–330 to +750 °F)
1 × sensor Prowirl 72 complete HT 3.1
50103481
4 × screw M5 × 12
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Sigraflex Z
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Viton
1 × gasket 25.0/20 × 0.8 mm (1.0/0.79 × 0.03 inch) Gylon
Kit DSC-sensor Prowirl 72, 77 Alloy C-22, 3.1
Alloy C-22, –200 to +400 °C (–330 to +750 °F)
1 × sensor Prowirl 72 complete HT C-22 3.1, 4 × screw M5 × 12
50103482
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Sigraflex Z
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Viton
1 × gasket 25.0/20 × 0.8 mm (1.0/0.79 × 0.03 inch) Gylon
Kit DSC-sensor Prowirl 72 high pressure 3.1
Inconel 718, –200 to +400 °C (–330 to +750 °F)
1 × sensor Prowirl 72 complete high pressure 3.1, 4 × screw M8 × 20
50103483
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Sigraflex HD
1 ×gasket 25.0/20 × 0.1 mm (1,0/0,79 × 0.04 inch) Viton
1 × gasket 25.0/20 × 0.8 mm (1,0/0,79 × 0.04 inch) Gylon
:
Order No Device component
Kit connection board Prowirl 72, 73 FS electronic Ex
50103884
1 × connection board L48 FS transmitter VDM Ex
Kit connection board Prowirl 72, 73 FS sensor Ex
50103885
1 × connection board L47 FS sensor VDM Ex
Kit gaskets housing Prowirl 72, 73 compact
1 × O-Ring 113.90 × 3.53 (4.48 × 0.14 inch) NBR
50103892
1 × O-Ring 49.21 × 3.53 (1.93 × 0.14 inch) NBR
1 × O-Ring 73.00 × 3.00 (2.87 × 0.12 inch) NBR
Kit gaskets housing Prowirl 72, 73 FS
2 × O-Ring 113.90 × 3.53 (4.48 × 0.14 inch)
50103893
2 × O-Ring 49.21 × 3.53 (1.93 × 0.14 inch)
1 × O-Ring 47.00 × 5.34 (1.85 × 0.21 inch)
2 × O-Ring 73.00 × 3.00 (2.87 × 0.12 inch)
Kit DSC-sensor PW73 high/low temperature
316L + Temp. Sensor, –200 to +400 °C (–330 to +750 °F)
1 × sensor Prowirl 73 complete thermal sensor
50106028
4 × screw M5 × 12
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Sigraflex
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Viton
1 × gaslet 25.0/20 × 0.8 mm (1.0/0.79 × 0.03 inch) Gylon
Kit DSC-sensor PW73 high/low temperature 3.1
316L + Temp. Sensor, –200 to +400 °C (–330 to +750 °F)
1 × sensor Prowirl 73 complete thermal sensor 3.1 B
50106029
4 × screw M5 × 12
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Sigraflex
1 × gasket 25.0/20 × 1.0 mm (1.0/0.79 × 0.04 inch) Viton
1 × gaslet 25.0/20 × 0.8 mm (1.0/0.79 × 0.03 inch) Gylon
Kit DSC-sensor Prowirl 72 max pressure 3.1
Titanium,–50 to +400 °C (–60 to +750 °F)
71023367
1 × sensor Prowirl W72 complete max pressure 3.1 Exd
4 × screw M10 × 35
1 × gasket 17.5/10 × 0.8 mm (0.68/0.4 × 0.04 inch) Grafoil
Kit gaskets housing 92F FS
3 × O-Ring 113.90 × 3.53 (4.48 × 0.14 inch)
71026988
1 × O-Ring 73.00 × 3.00 (2.87 × 0.12 inch)
1 × O-Ring 47.00 × 5.34 (1.85 × 0.21 inch)
1 × O-Ring 52.39 × 3.53 (2.06 × 0.14 inch)
Kit gaskets housing 92F compact
1 × O-Ring 113.90 × 3.53 (4.48 × 0.14 inch)
71026990
1 × O-Ring 73.00 × 3.00 (2.87 × 0.12 inch)
1 × O-Ring 47.00 × 5.34 (1.85 × 0.21 inch)
1 × O-Ring 52.39 × 3.53 (2.06 × 0.14 inch)

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Endress+Hauser Prowirl 73

  • Seite 1 316L + Temp. Sensor, –200 to +400 °C (–330 to +750 °F) Basic version, 316L, –40 to +260 °C, (–40 to +500 °F) 1 × sensor Prowirl 73 complete thermal sensor 3.1 B 1 × Sensor Prowirl 72 complete 3.1, 4 × screw M5 × 12...
  • Seite 2 The spare parts set and Installation Instructions are used to replace a faulty unit with a functioning unit of the same type.  Use genuine parts from Endress+Hauser only. Only original spare parts supplied by Endress+Hauser shall be used with the measuring device. Therefore, before use, check whether the spare part set is compatible with the measuring device.
  • Seite 3: Safety Instructions

    (for Ex. IECEx, ATEX, FM, CSA, TIIS, NEPSI) 1, 2, 3 1 Trained customer technician 1*Trained customer technician, trained by Endress+Hauser (for repairs carried out on devices with type approval) 2 Service technician authorized by Endress+Hauser 3 Endress+Hauser (send measuring device back to manufacturer) Safety instructions •...
  • Seite 4 Installing sensor parts A Removing transmitter compact- and remote version Prowirl 72, 73, Prosnic Flow 92 F 3 mm A0012506 A0012715 A0012557 A0012716 0.5 ×3.5 A0013456 A0013192 A0013209 A0012559 4 mm A0012561 A0012562 A0012563 A0013446 B Replacing gasket, O-Ring cover, connection board Prowirl 72, 73, Prosnic Flow 92 F remote version 0.5 ×3.5 8 mm A0013339...
  • Seite 5 Installing sensor parts C Replacing O-Ring cover, connection board Prowirl 72, 73 remote version 0.5 ×3.5 4 mm A0012718 A0012719 A0013343 A0013344 D Replacing O-Ring cover, connection board, gasket Prosonic Flow 92F remote version 3 mm 0.5 ×3.5 A0012995 A0013453 A0013448 A0013454 8 mm...
  • Seite 6 Installing sensor parts E Replacing sensor compact and remote version H Removing housing support High-/low temperature Replacing pre-amplifier, gasket " Caution! 1. The sealing surface must not get scratched. 2. Remove sealing disk using a suitable tool, without scratching the sealing surface.
  • Seite 7 Installing sensor parts L Removing housing support Max. pressure Replacing pre-amplifier, gasket 6 mm Pos. H A0016938 M Replacing DSC-sensor max. pressure 3.1, gasket Caution! To tighten the screws of the housing support and the sensor regard the bolting diagramm below and the table on page 8. 17 mm Pos.
  • Seite 8 Installing sensor parts Recomended torques position H = screws housing support position S = screws sensor 7****--**1********* 7****-**0********* 7****--**3********* 7****--**2********* 7****--**6********* 7****--**4********* graphic graphic graphic graphic graphic graphic graphic graphic chapter F chapter G chapter H chapter I chapter J chapter K chapter L chapter M...
  • Seite 9: Einbau Messaufnehmerteile

    Einbauanleitung Einbau Messaufnehmerteile Prowirl 72, 73, Prosonic Flow 92 F EA00042D/06/A2/14.12 71191695 Die Einbauanleitung ist für folgende Ersatzteilsets gültig: Bestell-Nr. Gerätekomponente Bestell-Nr. Gerätekomponente Set DSC-Sensor Prowirl 72 Standard 3.1 Basic version, 316L, –40 to +260 °C, (–40 to +500 °F) 1 ×...
  • Seite 10 (1,0/0,79 × 0,03 inch) Gylon Set DSC-Sensor PW73 Temperaturmessung 3.1 316L + Temperatur Sensor, –200…+400 °C (–330…+750 °F) 1 × DSC-Sensor Prowirl 73 Temperaturmessung 3.1 B 4 × Schraube M5 × 12 Set 5 Dichtungen Prowirl 77, 72, 73 HD 1 ×...
  • Seite 11: Überprüfung Ob Die Verwendung Des Ersatzteils Für Das Messgerät Erlaubt Ist

    Ersatzteilset und Einbauanleitung dienen dazu, eine defekte Einheit gegen eine funktionierende Einheit des gleichen Typs zu ersetzen. Es dürfen nur Originalteile von Endress+Hauser verwendet werden.. Grundsätzlich dürfen nur Ersteilsets verwendet werden, die von Endress+Hauser für das Messgerät vorgesehen sind. Vor der Verwendung ist deshalb zu überprüfen, ob das Ersteilsets zum Messgerät passt.
  • Seite 12: Sicherheitshinweise

    – Bei Ex-zertifizierten Messgeräten zusätzlich im Explosionsschutz • Die in der Betriebsanleitung aufgeführten Hinweise zum Transport ausgebildet und zur Rücksendung beachten. • Die Betriebsanleitung zum Messgerät ist zu beachten. • Bei Fragen kontaktieren Sie bitte Ihre zuständige Endress+Hauser Serviceorganisation. Werkzeugliste säurefreies, Stift/Werkzeug nicht härtendes...
  • Seite 13 Einbau Messaufnehmerteile 4 mm A0012561 A0012562 A0012563 A0013446 B Austausch Gehäusedichtung, O-Ring Deckel, Anschlussprint Prowirl 72, 73, Prosonic Flow 92 F Getrennt Version 0.5 ×3.5 8 mm A0013339 A0013338 A0013447 A0013448 A0013340 A0013452 C Austausch O-Ring Deckel, Anschlussprint Prowirl 72, 73 Getrennt Version 0.5 ×3.5 4 mm A0012718...
  • Seite 14 Einbau Messaufnehmerteile D Austausch O-Ring Deckel, Anschlussprint, Gehäusedichtung Prosonic Flow 92F Getrennt Version 3 mm 0.5 ×3.5 A0012995 A0013453 A0013448 A0013454 8 mm A0016923 E Austausch Sensor Kompakt- und Getrennt Version F Ausbau Gehäusestütze Standard Austausch Vorverstärker, Dichtung " Achtung! 1.
  • Seite 15 Einbau Messaufnehmerteile H Ausbau Gehäusestütze Hoch-/Tieftemperatur L Ausbau Gehäusestütze Höchste Drücke Austausch Vorverstärker, Dichtung Austausch Vorverstärker, Dichtung 6 mm 5 mm Pos. H Pos. H A0013368 A0016938 I Austausch DSC-Sensor Alloy C-22 3.1 M Austausch DSC-Sensor Höchste Drücke 3.1, Dichtung oder DSC-Sensor Hoch-/Tieftemperatur 3.1...
  • Seite 16: Empfohlene Drehmomente

    Einbau Messaufnehmerteile Empfohlene Drehmomente Position H = Schrauben Gehäusestütze Position S = Schrauben Sensor 7****--**1********* 7****-**0********* 7****--**3********* 7****--**2********* 7****--**6********* 7****--**4********* siehe siehe siehe siehe siehe siehe siehe siehe Grafik Grafik Grafik Grafik Grafik Grafik Grafik Grafik Kapitel F Kapitel G Kapitel H Kapitel I Kapitel J...