If an electric fan is used for extracting the combustion
products, the ventilation aperture must be increased in
relation to its maximum performance. The electric fan
should have a sufficient capacity to guarantee an hourly
exchange of air equal to 3-5 times the volume of the
kitchen.
Prolonged, intensive use of the appliance may require
extra ventilation, e.g. an open window or a more efficient
ventilation system by increasing the extraction power of
the electric fan if installed.
Liquid petroleum gas descends towards the floor as it is
heavier than air. Apertures in the outside walls in rooms
containing LPG cylinders should therefore be at floor level,
in order to allow any gas from leaks to be expelled. Do
not store LPG cylinders (even when empty) in basements/
rooms below ground level; it is advisable to keep only the
cylinder in use in the room at any one time and connected
far from heat sources which could raise its temperature to
above 50 °C.
Installation
These instructions are given for a class 1 and category
II 2H3+ appliance.
Suitable precautions must be taken to ensure that the
installation is in compliance with current accident-
prevention regulations regarding electrical and gas
connections.
When installing above a built-under oven, suitable air vents
A
180cm²
fig.4
should be provided for as shown in fig.4 (inlet at least 200
cm² from the bottom, outlet at least 180 cm² from the top
part) to allow adequate ventilation inside the housing unit.
Both the electricity supply cable and the gas pipe must
not touch hot parts of the oven housing, in order to avoid
overheating.
When installing above a built-under oven without forced
cooling ventilation, a wooden panel "A" (fig.4) should be
installed beneath the hob as insulation, positioning it at a
minimum distance of 15 mm from the hob housing.
For trouble-free operation of the appliance set into kitchen
units, the minimum distances indicated in fig.5 should be
complied with.
The hob has a protection rating Y against overheating, in
accordance with standard EN60335-2-6. The surfaces
adjoining the unit and the wall to the rear should be in
suitable material to withstand a temperature of 65°C.
To fix the hob to the unit, proceed as follows (fig.6);
• tighten 2 screws "A" (provided) into the unit, leaving the
screw heads projecting 1.5 mm from the wood;
• hook the hob onto the 2 screws "A" and push backwards;
• fix the hob to the unit at the rear using the 2 corner
brackets "B" and the 4 screws "C" provided.